MNC-0400-001 31 of 54 REV H
Operation, Rack and Digital HPAs
Constant Power Sub-menu
The amplifiers can be setup to automatically maintain RF output
power at a preset level. The front panel 10-key pad and one of
the softkeys of this menu are active. The softkey functions are:
[Softkey 1]—Enables or disables the Constant Power function.
Toggles between ON and OFF.
[Softkey 2]—Not Used. Value shown to the left of this key is the
current setting. See Note 1 in Figure 11.
[Softkey 3]—Not Used.
[Softkey 4]—Not Used.
Offset Factor Menu
This menu allows offset of RF power output to compensate for
waveguide losses and antenna gain. The front panel 10-key pad
and three of the softkeys are active. The front panel 10-key pad
is used to enter the desired adjustment (in dB).
The functions of the softkeys are:
[Softkey 1]—Not Used.
[Softkey 2]—Value shown to the left of this key is the current
setting. Pressed to Changes polarity of the adjustment. Toggles
between (+) and (-).
[Softkey 3]—Not Used. Value entered for the new value on the
numeric keypad shows up to the left of the soft key. Press
[Enter] to accept your entry. Press [Clear] to clear your entry.
[Softkey 4]—Go back to the previous menu.
EAR EXPORT CONTROLLED: The information contained in this Manual refers or relates to a product that is subject
to the U.S. Export Administration Regulations (EAR). Transfer of data herein by any means to a Foreign Person,
whether in the U.S. or abroad, may require an export license from the U.S. Department of Commerce.