Comtech EF Data KPA-040 Manual de instalación Pagina 138

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 183
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 137
MNC-0500-002 26 of 36 Revision H
Amplifier Communication and Protocol, Octagon ISA CPU
Amplifier Commands
AC Power
Command Byte: '!'
Function: Enables/Disables AC power to the HPA.
Parameters:
'0' - Disable AC power.
'1' - Enable AC power.
Compatibility: This command is only available for ODUs connected to a controller.
The controller will intercept the command and enable or disable power to the specified
amplifier.
Heater Standby
Command Byte: ':'
Function: Enables/Disables Heater Standby mode.
Parameters:
'0' - Disable Heater Standby.
'1' - Enable Heater Standby.
High Voltage On
Command Byte: '@'
Function: Turns high voltage on. If the unit is in Filament Time Delay, high voltage will
automatically turn on when Filament Time Delay ends.
High Voltage Off
Command Byte: 'A'
Function: Turns off high voltage. If the unit is in Filament Time Delay, this command
ensures that high voltage will not turn on when Filament Time Delay ends.
EAR EXPORT CONTROLLED: The information contained in this Manual refers or relates to a product that is subject
to the U.S. Export Administration Regulations (EAR). Transfer of data herein by any means to a Foreign Person,
whether in the U.S. or abroad, may require an export license from the U.S. Department of Commerce.