Comtech EF Data KPA-040 Manual de instalación Pagina 146

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 183
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 145
MNC-0500-002 34 of 36 Revision H
Amplifier Communication and Protocol, Octagon ISA CPU
Simulate Front Panel Input, Continued
Alternate Parameters (for Xicom's digital outdoor controller):
'L': Toggle Local/Remote.
'A': Toggle HPA/AC Power.
'H': Toggle HPA heater standby.
'!': Toggle HPA High Voltage.
'F': Fault Reset.
'8': Up Arrow.
'E': Enter.
'2': Down Arrow.
Notes:
If communicating with an amplifier via Xicom's digital outdoor controller, reference the alternate
parameter list. Otherwise, use the standard parameter list.
Rack amplifiers normally require that the enable key be pressed to process certain front panel
inputs. However, this is not a requirement for processing simulated front panel input.
Parameters 'I', 'J', 'K', and 'L' initiate Goto Power sequences (see commands 'D' and 'E', Goto
Power.) Goto Power sequences typically take several seconds for the power to reach the
desired level. For faster response, use parameters 'i', 'j', 'k', and 'l', which simulate encoder shaft
input. However, the HPA must be in the correct screen (i.e. Status1). The encoder shaft is also
used to scroll the fault log screen and to adjust settings on the linearization screen.
EAR EXPORT CONTROLLED: The information contained in this Manual refers or relates to a product that is subject
to the U.S. Export Administration Regulations (EAR). Transfer of data herein by any means to a Foreign Person,
whether in the U.S. or abroad, may require an export license from the U.S. Department of Commerce.
Vista de pagina 145
1 2 ... 141 142 143 144 145 146 147 148 149 150 151 ... 182 183

Comentarios a estos manuales

Sin comentarios