MNC-0400-001 14 of 54 REV H
Operation, Rack and Digital HPAs
Two of the Status 1 Menu softkeys are active. The functions of
the active Status 1 Menu softkeys are:
[Softkey 1]--Temporarily changes the units used for the RF
power data display. Cycles one step each time [Softkey1] key is
pressed. There are three data displays available.
Step sequence is:
Watts dBm dBw Watts
[Softkey 3]--Temporarily changes the temperature units used
for the temperature data display. Toggles between degrees F
(Fahrenheit) and degrees C (Centigrade) each time [Softkey 3]
is pressed.
Note
When High Voltage Is ON the Status 1 Screen shows:
Power Out
Rfltd Pwr
TWT Temp
Helix I
Press and Hold [Enable]. The screen displays Atten Set.
When High Voltage is OFF the Status 1 Screen shows:
HV OFF
Atten Set
TWT Temp
Helix I
Pressing and Holding [Enable] has no effect.