5.0 TESTING REQUIREMENTS
5.1 Acceptance Test Procedure (ATP) requirements.
Frequency 3.1.1
Power 3.1.2
Transfer curve at mid-band 3.1.2
Gain, large signal 3.1.3
Gain, small signal 3.1.4
Gain flatness, small signal 3.1.5.1, 3.1.5.2, 3.1.5.3
Gain Control 3.1.6
Spurious signals 3.1.14
Prime Power 3.1.16
Sample Port Calibration N/A
5.2 First Article Test Procedure (FAT) requirements.
FAT testing is done per the specified agreements between Xicom and it’s customers.
The FAT test shall include at a minimum the ATP. Please specify the FAT
requirements at the time of order of the product.
EAR EXPORT CONTROLLED: The information contained in this Manual refers or relates to a product that is subject
to the U.S. Export Administration Regulations (EAR). Transfer of data herein by any means to a Foreign Person,
whether in the U.S. or abroad, may require an export license from the U.S. Department of Commerce.