UT-4500-A Series Upconverters Revision 1
Front Panel Operation MN-UT4500A
5–13
Conv Temperature = OK ▲
High Speed Bus = OK ▼
Press ENTER or CLEAR to continue.
5.3.3.2 FAULTS: STORED (Stored Faults Log)
VIEW CLEAR-ALL
Use the
◄ ► arrow keys to select View or Clear-All, and then press ENTER.
FAULTS: STORED VIEW
If View is selected and no faults exist, the system displays the following message:
No Stored Faults.
The faults log can store up to 100 faults. When a fault condition occurs, it is date- and time-
stamped, and stored in the faults log with a number assigned in the order received. The fault
information displays as per the following example:
Log05 01/23/11 09:27:15▲
Fault – HSB ▼
When the fault condition clears, this is also recorded in the same fashion as the fault was
originally recorded, as shown per the following example:
Log09 01/23/11 10:45:35▲
Clear – HSB ▼
The stored faults remain in memory until the CLEAR-ALL command is entered. When the
number of faults reaches 100, the 100
th
fault will display ER.
You may use the
▲ ▼ arrow key to scroll backwards or forwards through the faults log.
Press ENTER or CLEAR to return to the previous menu.
FAULTS: STORED CLEAR-ALL
Clear All Stored Faults
No Yes
Use the
◄ ► arrow keys to choose No or Yes, and then press ENTER.