UT-4500-A Series Upconverters Revision 1
Front Panel Operation MN-UT4500A
5–13
Conv Temperature = OK
High Speed Bus = OK
Press ENTER or CLEAR to continue.
5.3.3.2 FAULTS: STORED (Stored Faults Log)
VIEW CLEAR-ALL
Use the
◄ ► arrow keys to select View or Clear-All, and then press ENTER.
FAULTS: STORED VIEW
If View is selected and no faults exist, the system displays the following message:
No Stored Faults.
The faults log can store up to 100 faults. When a fault condition occurs, it is date- and time-
stamped, and stored in the faults log with a number assigned in the order received. The fault
information displays as per the following example:
Log05 01/23/11 09:27:15
Fault – HSB
When the fault condition clears, this is also recorded in the same fashion as the fault was
originally recorded, as shown per the following example:
Log09 01/23/11 10:45:35
Clear – HSB
The stored faults remain in memory until the CLEAR-ALL command is entered. When the
number of faults reaches 100, the 100
th
fault will display ER.
You may use the
arrow key to scroll backwards or forwards through the faults log.
Press ENTER or CLEAR to return to the previous menu.
FAULTS: STORED CLEAR-ALL
Clear All Stored Faults
No Yes
Use the
◄ ► arrow keys to choose No or Yes, and then press ENTER.