UT-4500-A Series Upconverters Revision 1
Appendix A MN-UT4500A
A–22
A.7.4.3 Utility Status
COMM_aaaaaa'cr' RS-232 or RS-485
ADD_xxx'cr' Address (001 to 255)
BR_nnnn'cr' Baud Rate (1200, 2400, 4800, 9600,
19K2, or 38K4)
FMT_x-y-z’cr’ Data Format x=data, y=parity, z=stop
bit (8-N-1, 7-E-2, 7-O-2)
REF_xxx'cr' Osc. Adjust (000 to 255)
SLP_x.x'cr' Slope Adjust (0.0 to 1.0)
CON_xx'cr' LCD Contrast (0 to 30)
LCD_xx'cr''lf'] LCD Brightness (0 to 30).
A.7.4.4 Alarm Status
P14_xx'cr' 14 Vdc Fault
VCC_xx'cr' VCC Fault
5VD_xx'cr' 5VD Fault
TEM_xx'cr' Temperature Fault
IFL_xx'cr' IFLO Lock Fault
SUM_xx'cr' Sum Lock Fault
COR_xx'cr' Coarse Lock Fault
FIN_xx'cr'Fine lock Fault
HSB_xx’cr’ High Speed Bus Fault
*REF_xx'cr''lf'] Ref. Lock Fault
Note: REF_xx is only returned if an external reference is present.
A.7.4.5 Summary Alarm Status
Summary alarm is set to Fault (FT) if any items in Sect. A.7.4.4 are faulted.
<DEV/SAS_'cr' xx = OK or FT
Comentarios a estos manuales