UT-4500-A Series Upconverters Revision 1
Appendix A MN-UT4500A
A–22
A.7.4.3 Utility Status
Command
Details
Utility Status:
<DEV/RUS_'cr'
Confirmation:
>DEV/RUS_'cr'
COMM_aaaaaa'cr' RS-232 or RS-485
ADD_xxx'cr' Address (001 to 255)
BR_nnnn'cr' Baud Rate (1200, 2400, 4800, 9600,
19K2, or 38K4)
FMT_x-y-z’cr’ Data Format x=data, y=parity, z=stop
bit (8-N-1, 7-E-2, 7-O-2)
REF_xxx'cr' Osc. Adjust (000 to 255)
SLP_x.x'cr' Slope Adjust (0.0 to 1.0)
CON_xx'cr' LCD Contrast (0 to 30)
LCD_xx'cr''lf'] LCD Brightness (0 to 30).
A.7.4.4 Alarm Status
Command
Details
Alarm Status:
<DEV/RAS_'cr'
Confirmation:
>DEV/RAS_'cr'
P15_xx'cr' 15 Vdc Fault
P14_xx'cr' 14 Vdc Fault
VCC_xx'cr' VCC Fault
5VD_xx'cr' 5VD Fault
TEM_xx'cr' Temperature Fault
IFL_xx'cr' IFLO Lock Fault
SUM_xx'cr' Sum Lock Fault
COR_xx'cr' Coarse Lock Fault
FIN_xx'cr'Fine lock Fault
HSB_xx’cr’ High Speed Bus Fault
*REF_xx'cr''lf'] Ref. Lock Fault
xx = OK or FT
Note: REF_xx is only returned if an external reference is present.
A.7.4.5 Summary Alarm Status
Summary alarm is set to Fault (FT) if any items in Sect. A.7.4.4 are faulted.
Command
Details
Summary Alarm:
<DEV/SAS_'cr' xx = OK or FT
Confirmation:
>DEV/SAS_xx'cr''lf']