UT-4500-A Series Upconverters Revision 1
Appendix A MN-UT4500A
A–21
A.7.4 Status Commands
Status commands retrieve configuration, maintenance and alarm status in summary form.
A.7.4.1 Configuration Status
FRE_xxxxx.xxx'cr' Frequency
ATT_yy.yy'cr' Attenuator
TX_nnn'cr' Transmitter - ON/OFF/COLD
ONL_nnn'cr' Online - ON/OFF
RED_xx_yy_z'cr' See Note
CLD_nnn'cr' Cold Start - ON/OFF
AFR_nnn'cr' Auto Flt Recovery-ON/OFF
EXT_xxx'cr''lf'] Ext. Ref. - YES/NO
Note: If Redundancy OFF xx_yy_z = OFF, else if Redundancy ON and converter selected as
backup controller xx_yy_z = BU_yy where yy is the number of converters in the chain (i.e. 01 to
12), else if Redundancy ON and converter selected as a chain unit xx is the converter number (01
to 12), and z = A if Auto Mode or M if Manual Mode.
A.7.4.2 Maintenance Status
P15_xx.x'cr' 15 Vdc Supply
P14_xx.x'cr' 14 Vdc Supply
VCC_x.x'cr' VCC Supply
5VD_x.x'cr' Display 5 Vdc
TEM_xx'cr' Temperature
IFL_xx.x'cr' IFLO Tuning
SUM_xx.x'cr' Sum Loop Tuning
COR_xx.x'cr' Coarse Loop Tune
FIN_xx.x'cr''lf'] Fine Loop Tuning.