UT-4500-A Series Upconverters Revision 1
Front Panel Operation MN-UT4500A
5–12
5.3.2 MONITOR
Three read-only information screens are provided to monitor a number of operating voltage,
temperature and tuning parameters. Use the
arrow keys to page between screens.
The following examples are provided for informational purposes only the data displayed here
for each parameter will vary depending on the operating conditions for the system in use:
15VDC=15.6V 14VDC=14.0V
VCC=0.5V 5VDis=0.50V
Converter Temp = +30.0C
IFLO Tuning = 0.38V
Synth Tuning: Sum=0.32V
Coarse=06.0V Fine=03.5V
Press ENTER or CLEAR to continue.
5.3.3 FAULTS
CURRENT STORED
Use the
◄ ► arrow keys to select CURRENT or STORED, and then press ENTER.
5.3.3.1 FAULTS: CURRENT
Four read-only information screens are provided to monitor a number of operating parameters
and return back whether the parameters are OK i.e., operating within normal ranges, or FT
i.e., currently faulted. Use the
arrow keys to page between screens.
The following examples are provided for information purposes only the data displayed here
will vary depending on the operating conditions for the system in use:
Power Faults: 15VDC=OK
14VDC=OK VCC=OK
IFLO Lock Detect = OK
Synth Faults: SumLD=OK
FineLD=OK CoarseLD=OK