Comtech EF Data Vipersat CDM-570 Guía de usuario Pagina 177

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 192
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 176
Appendix D - ECM Migration D-7
Migration Procedure
Example: The recommended settings for 64 kbps, QPSK, 3/4
Guardband—60 msec
Preamble Length—300 msec
Total Slot Count—10
Tip: A Vipersat calculator is available to optimize these settings. Contact a
Comtech Vipersat Networks representative for a copy of the latest
Vipersat ECM Calculator.
There is no Remote List for ECMv2 like there is for ECMv1. Therefore, there is
no need to enable the Remotes in the burst map, nor to set a desired dSCPC
switch rate.
With ECMv2, the Remote sites will switch out to dSCPC using the Minimum
Switch Rate Limit from the Inband Return Path settings, as shown in
figure D-4 below.
Figure D-4
Switch Rate Limits, InBand Return Path Settings Page
Vista de pagina 176
1 2 ... 172 173 174 175 176 177 178 179 180 181 182 ... 191 192

Comentarios a estos manuales

Sin comentarios