Pagina 1 - CRS-300

IMPORTANT NOTE: The information contained in this document supersedes all previously published information regarding this product. Product specifica

Pagina 2

CRS-300 1:10 Redundancy Switch Revision 16 Table of Contents MN/CRS300.IOM viii 7.3 SELECT (Top-Level) Menu ...

Pagina 3

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–40 4.6 CDM-Qx/QxL Modem Connections If adding a modem to an ope

Pagina 4

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–41 Figure 4-16. EIA-485 Multi-drop Cabling Example – CRS-

Pagina 5 - Table of Contents

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–42 4.6.3 Control Y-Cable Connections – CRS-300 to Modems All tra

Pagina 6

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–43 Next, connect and secure the (4X) Quad E1 TMI Data Cables (CEF

Pagina 7

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–44 Figure 4-17. Control Y-Cables and EIA-530/-232 Data Ca

Pagina 8

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–45 Figure 4-18. Control Y-Cables and Balanced G.703 Data C

Pagina 9

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–46 Figure 4-19. Control Y-Cables and Unbalanced G.703 Data

Pagina 10

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–47 Figure 4-20. Control Cables and HSSI Data Cables – CRS-

Pagina 11

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–48 Figure 4-21. Control Cables and Quad E1 Data Cables – C

Pagina 12

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–49 4.7 CDM-700 Modem Connections o Interface Co

Pagina 13 - Figures

CRS-300 1:10 Redundancy Switch Revision 16 Table of Contents MN/CRS300.IOM ix A.3.5 Optional EIA-485 Multi-drop Ribbon Cable, (15X) DB-9 Female

Pagina 14

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–50 4.7 CDM-700 Modem Connections If adding a modem to an operat

Pagina 15

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–51 2. The Traffic CDM-700 must have the same interface cards in

Pagina 16

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–52 4.7.5 Ethernet Traffic Data Connections - CRS-300 to Modems T

Pagina 17 - PREFACE

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–53 Figure 4-22. Control and Traffic Data Cables Example #1 – CR

Pagina 18 - Preface MN/CRS300.IOM

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–54 Figure 4-23. Control and Traffic Data Cables Example #2 – C

Pagina 19 - Low Voltage Directive (LVD)

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–55 Figure 4-24. CDM-700 IP Connections – Wired-thru Example #1

Pagina 20 - Limitations of Warranty

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–56 Figure 4-25. CDM-700 IP Connections – Wired-thru Example #2 (

Pagina 21 - Exclusive Remedies

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–57 Figure 4-26. CDM-700 IP Connections – Wired-around Example #1

Pagina 22 - Online Customer Support

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–58 Figure 4-27. CDM-700 IP Connections – Wired-around Example #2

Pagina 23 - Chapter 1. INTRODUCTION

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–59 4.8 CDM-710 Modem Connections o Interface C

Pagina 24 - Introduction MN/CRS300.IOM

CRS-300 1:10 Redundancy Switch Revision 16 Table of Contents MN/CRS300.IOM x C.5 Packet Structure ...

Pagina 25

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–60 4.8 CDM-710 Modem Connections If adding a modem to an operat

Pagina 26 - 1.2 CRS-300 Compatibility

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–61 4.8.3 Control Cable Connections – CRS-300 to Modems The Contr

Pagina 27

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–62 Figure 4-28. Control and Data Cables Example #1 – CRS-300 t

Pagina 28

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–63 Figure 4-29. Control and Data Cables Example #2 – CRS-300

Pagina 29 - 1.4.1 Front Panel

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–64 Notes:

Pagina 30 - 1.4.2 Rear Panel

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–65 4.9 CDM-710G Modem Connections o Interfac

Pagina 31

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–66 4.9 CDM-710G Modem Connections If adding a modem to an opera

Pagina 32

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–67 4.9.3 Control Cable Connections – CRS-300 to Modems The Contr

Pagina 33 - SLM-5650/5650A

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–68 Figure 4-30. Control and Data Cables Example #1 – CRS-30

Pagina 34

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–69 Figure 4-31. Control and Data Cables Example #2 – CRS-3

Pagina 35

CRS-300 1:10 Redundancy Switch Revision 16 Table of Contents MN/CRS300.IOM xi Figures Figure 1-1. Typical Redundancy System-Level Block Diagram .

Pagina 36

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–70 Notes:

Pagina 37

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–71 4.10 SLM-5650/5650A Modem Connections o Co

Pagina 38

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–72 4.10 SLM-5650/5650A Modem Connections If adding a modem to an

Pagina 39

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–73 • HSSI (HD-50F) connector labeled “J2” on the RMI or “J3” on

Pagina 40

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–74 4.10.4 User Data Connections – CRS-300 to User The User’s tra

Pagina 41 - 1.6.5 Dimensional Envelopes

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–75 Figure 4-32. Control and Data Cables Example #1 – CRS-300 to

Pagina 42

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–76 Figure 4-33. Control and Data Cables Example #2 – CRS-300 to

Pagina 43

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–77 Figure 4-34. Control and Data Cables Example #3 – CRS-300

Pagina 44

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–78 Figure 4-35. Cabling Example for CRS-350 to SLM-565

Pagina 45 - Chapter 2. INSTALLATION

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–79 4.11 IF Cable Connections o Single Tr

Pagina 46 - Installation MN/CRS300.IOM

CRS-300 1:10 Redundancy Switch Revision 16 Table of Contents MN/CRS300.IOM xii Figure 4-2. Control Cable Connection Example for CRS-300 ÆCRS-280L

Pagina 47

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–80 4.11 IF Cable Connections There are two different possible IF

Pagina 48

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–81 Figure 4-36. IF Cabling Example 1 – Single Transponder C

Pagina 49

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–82 4.11.2 Multiple Transponder IF Connections (Using IF Switch)

Pagina 50

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–83 Figure 4-37. Multiple Transponder IF Connection Cablin

Pagina 51

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–84 Notes:

Pagina 52

5–1 Chapter 5. MODEM, RMI/TMI, AND SWITCH CONFIGURATION 5.1 Overview IMPOR TANT In order to avoid damage to the modems and CRS-300 switch, it is impo

Pagina 53

CRS-300 1:10 Redundancy Switch Revision 16 Modem, RMI/TMI, and Switch Configuration MN/CRS300.IOM 5–2 5.2 Modem Configuration 5.2.1 Modem Power Co

Pagina 54

CRS-300 1:10 Redundancy Switch Revision 16 Modem, RMI/TMI, and Switch Configuration MN/CRS300.IOM 5–3 changing configuration settings using the fron

Pagina 55

CRS-300 1:10 Redundancy Switch Revision 16 Modem, RMI/TMI, and Switch Configuration MN/CRS300.IOM 5–4 5.2.4.2.1 CDM-625 Redundancy Configuration wi

Pagina 56

CRS-300 1:10 Redundancy Switch Revision 16 Modem, RMI/TMI, and Switch Configuration MN/CRS300.IOM 5–5 5.2.4.3 Switch to CDM-700, CDM-710, CDM-710G

Pagina 57

CRS-300 1:10 Redundancy Switch Revision 16 Table of Contents MN/CRS300.IOM xiii Figure A-2. DCE Conversion Cable: EIA-530 to V.35 ...

Pagina 58

CRS-300 1:10 Redundancy Switch Revision 16 Modem, RMI/TMI, and Switch Configuration MN/CRS300.IOM 5–6 5.2.4.4 Switch to SLM-5650/5650A Redundancy C

Pagina 59

CRS-300 1:10 Redundancy Switch Revision 16 Modem, RMI/TMI, and Switch Configuration MN/CRS300.IOM 5–7 Furthermore, in Ethernet Bridge Mode, the para

Pagina 60

CRS-300 1:10 Redundancy Switch Revision 16 Modem, RMI/TMI, and Switch Configuration MN/CRS300.IOM 5–8 5.2.4.5 Switch to CDM-Qx/QxL Redundancy Confi

Pagina 61 - CABLES AND CONNECTIONS

CRS-300 1:10 Redundancy Switch Revision 16 Modem, RMI/TMI, and Switch Configuration MN/CRS300.IOM 5–9 Figure 5-2. CDM-Qx/QxL / CRS-300 EIA-485 Sch

Pagina 62

CRS-300 1:10 Redundancy Switch Revision 16 Modem, RMI/TMI, and Switch Configuration MN/CRS300.IOM 5–10 5.3 RMI Card Configuration Reference IMPORTA

Pagina 63

CRS-300 1:10 Redundancy Switch Revision 16 Modem, RMI/TMI, and Switch Configuration MN/CRS300.IOM 5–11 5.4 TMI Card Configuration Reference The fol

Pagina 64

CRS-300 1:10 Redundancy Switch Revision 16 Modem, RMI/TMI, and Switch Configuration MN/CRS300.IOM 5–12 Table 5-2. CRS-316 Jumper ‘JP1’ Settings Use

Pagina 65

CRS-300 1:10 Redundancy Switch Revision 16 Modem, RMI/TMI, and Switch Configuration MN/CRS300.IOM 5–13 5.4.2 EIA-232/-422, V.35 Interfaces via the

Pagina 66

CRS-300 1:10 Redundancy Switch Revision 16 Modem, RMI/TMI, and Switch Configuration MN/CRS300.IOM 5–14 Table 5-5 illustrates the control signal conf

Pagina 67

CRS-300 1:10 Redundancy Switch Revision 16 Modem, RMI/TMI, and Switch Configuration MN/CRS300.IOM 5–15 5.4.3 HSSI Interfaces via the CRS-336 TMI Fi

Pagina 68

CRS-300 1:10 Redundancy Switch Revision 16 Table of Contents MN/CRS300.IOM xiv This page is intentionally blank.

Pagina 69

CRS-300 1:10 Redundancy Switch Revision 16 Modem, RMI/TMI, and Switch Configuration MN/CRS300.IOM 5–16 Table 5-6. CRS-336 Jumper ‘JP1’ Settings Use

Pagina 70

CRS-300 1:10 Redundancy Switch Revision 16 Modem, RMI/TMI, and Switch Configuration MN/CRS300.IOM 5–17 5.4.4 HSSI Interface via the CRS-370 TMI Jum

Pagina 71

CRS-300 1:10 Redundancy Switch Revision 16 Modem, RMI/TMI, and Switch Configuration MN/CRS300.IOM 5–18 5.5 Switch Configuration 5.5.1 Switch Power

Pagina 72

CRS-300 1:10 Redundancy Switch Revision 16 Modem, RMI/TMI, and Switch Configuration MN/CRS300.IOM 5–19 5.5.2 Flash Updating The CRS-300 eliminates t

Pagina 73

CRS-300 1:10 Redundancy Switch Revision 16 Modem, RMI/TMI, and Switch Configuration MN/CRS300.IOM 5–20 3. Download the correct firmware file to thi

Pagina 74

CRS-300 1:10 Redundancy Switch Revision 16 Modem, RMI/TMI, and Switch Configuration MN/CRS300.IOM 5–21 6. Run the Upload utility. The User should f

Pagina 75

CRS-300 1:10 Redundancy Switch Revision 16 Modem, RMI/TMI, and Switch Configuration MN/CRS300.IOM 5–22 To deactivate a modem, see Chapter 7.4.5

Pagina 76

CRS-300 1:10 Redundancy Switch Revision 16 Modem, RMI/TMI, and Switch Configuration MN/CRS300.IOM 5–23 To enable Auto mode: Step Procedure 1 Go to

Pagina 77

CRS-300 1:10 Redundancy Switch Revision 16 Modem, RMI/TMI, and Switch Configuration MN/CRS300.IOM 5–24 5.5.3.4.2 Set Restore Holdoff Period The &qu

Pagina 78

6–1 Chapter 6. CONNECTOR PINOUTS 6.1 CRS-230 Controller Connectors 6.1.1 IF Switch Control – DB-25M Connector The DB-25M IF Switch

Pagina 79

xvPREFACE About this Manual This manual provides installation and operation information for the Comtech EF Data CRS-300 1:10 Redundancy Switch. Thi

Pagina 80

CRS-300 1:10 Redundancy Switch Revision 16 Connector Pinouts MN/CRS300.IOM 6–2 6.1.2 485 Pass-Through – DB-9F Connector Table 6-1 indicates the pi

Pagina 81

CRS-300 1:10 Redundancy Switch Revision 16 Connector Pinouts MN/CRS300.IOM 6–3 6.1.4 System Alarms – DB-25F Connector Table 6-3 indicates the pino

Pagina 82 - (CnC) Data Connections

CRS-300 1:10 Redundancy Switch Revision 16 Connector Pinouts MN/CRS300.IOM 6–4 6.2 TMI User Data Connectors 6.2.1 EIA-232/422/V.35 – DB-25F Conne

Pagina 83 - Cable Connection Example

CRS-300 1:10 Redundancy Switch Revision 16 Connector Pinouts MN/CRS300.IOM 6–5 6.2.2 EIA-232/422/V.35/LVDS – DB-25F Connector (CRS-320/340)

Pagina 84

CRS-300 1:10 Redundancy Switch Revision 16 Connector Pinouts MN/CRS300.IOM 6–6 6.2.3 ASI – BNC Connectors (CRS-325) Table 6-6 indicates the

Pagina 85

CRS-300 1:10 Redundancy Switch Revision 16 Connector Pinouts MN/CRS300.IOM 6–7 6.2.5 Balanced G.703 – DB-15F Connector (CRS-325/330/340)

Pagina 86

CRS-300 1:10 Redundancy Switch Revision 16 Connector Pinouts MN/CRS300.IOM 6–8 6.2.6 Unbalanced G.703 – BNC Connectors (CRS-325/330/340)

Pagina 87

CRS-300 1:10 Redundancy Switch Revision 16 Connector Pinouts MN/CRS300.IOM 6–9 6.2.8 HSSI – HD-50F Connector (CRS-336/370) Table 6-11 is

Pagina 88

CRS-300 1:10 Redundancy Switch Revision 16 Connector Pinouts MN/CRS300.IOM 6–10 6.2.9 10/100/1000 Ethernet – RJ-45F Connector (CRS-316/336)

Pagina 89 - Notes 2,3

CRS-300 1:10 Redundancy Switch Revision 16 Connector Pinouts MN/CRS300.IOM 6–11 6.2.10 Quad E1 – RJ-48F Connectors (CRS-365) Table 6-13 indi

Pagina 90

CRS-300 1:10 Redundancy Switch Revision 16 Preface MN/CRS300.IOM xvi Conventions and References Cautions and Warnings IMPOR TANT IMPORTANT or NOTE

Pagina 91

CRS-300 1:10 Redundancy Switch Revision 16 Connector Pinouts MN/CRS300.IOM 6–12 6.2.11 Quad E1 – DB-9F Connectors (CRS-365D) Table 6-14 and

Pagina 92

7–1 Chapter 7. FRONT PANEL OPERATION 7.1 Introduction Modem Status Unit Status Vacuum Fluorescent LED Indicators

Pagina 93

CRS-300 1:10 Redundancy Switch Revision 16 Front Panel Operation MN/CRS300.IOM 7–2 7.1.1 Front Panel Keypad The CRS-300 front panel keypad contain

Pagina 94

CRS-300 1:10 Redundancy Switch Revision 16 Front Panel Operation MN/CRS300.IOM 7–3 7.1.2 Front Panel LED Indicators 7.1.2.1 Unit Status LED Indica

Pagina 95

CRS-300 1:10 Redundancy Switch Revision 16 Front Panel Operation MN/CRS300.IOM 7–4 7.1.2.2 Modem Status LED Indicators The behavior of the six fr

Pagina 96 - Emulation Mode

CRS-300 1:10 Redundancy Switch Revision 16 Front Panel Operation MN/CRS300.IOM 7–5 7.1.3 Front Panel Vacuum Fluorescent Display (VFD) The Front Pan

Pagina 97

CRS-300 1:10 Redundancy Switch Revision 16 Front Panel Operation MN/CRS300.IOM 7–6 7.2 CRS-300 Menu Structure Figure 7-2 shows the menu structure o

Pagina 98

CRS-300 1:10 Redundancy Switch Revision 16 Front Panel Operation MN/CRS300.IOM 7–7 7.3 SELECT (Top-Level) Menu SELECT: CONFIG INFO MONI

Pagina 99

CRS-300 1:10 Redundancy Switch Revision 16 Front Panel Operation MN/CRS300.IOM 7–8 7.4.1 CONFIG: MANUAL MANUAL SELECT: BRIDGE:02 BACKUP:02 Th

Pagina 100 - MPORTANT

CRS-300 1:10 Redundancy Switch Revision 16 Front Panel Operation MN/CRS300.IOM 7–9 7.4.3 CONFIG: OPTIONS OPTIONS: PRIORITY HOLDOFFS AL

Pagina 101

CRS-300 1:10 Redundancy Switch Revision 16 Preface MN/CRS300.IOM xvii EN55024 - 1998 Compliance This equipment meets the EMC/immunity characteristic

Pagina 102

CRS-300 1:10 Redundancy Switch Revision 16 Front Panel Operation MN/CRS300.IOM 7–10 CONFIG: OPTIONS Æ ALARM-MASK If ALARM-MASK is selected: ALARM

Pagina 103

CRS-300 1:10 Redundancy Switch Revision 16 Front Panel Operation MN/CRS300.IOM 7–11 7.4.4 CONFIG: REMOTE SELECT REMOTE CONTROL: LOCAL REMOTE (PR

Pagina 104

CRS-300 1:10 Redundancy Switch Revision 16 Front Panel Operation MN/CRS300.IOM 7–12 EDIT SWITCH BUS ADDRESS: 3000 (PRESS ENTER) The value

Pagina 105

CRS-300 1:10 Redundancy Switch Revision 16 Front Panel Operation MN/CRS300.IOM 7–13 • If desired, the User can go to Manual mode, switchover the a

Pagina 106

CRS-300 1:10 Redundancy Switch Revision 16 Front Panel Operation MN/CRS300.IOM 7–14 7.5.5 INFO: REMCONT (Remote Control Info) REM CNTL: ON R

Pagina 107

CRS-300 1:10 Redundancy Switch Revision 16 Front Panel Operation MN/CRS300.IOM 7–15 7.6.2 MONITOR: SW-ALARM The following are examples of possible

Pagina 108

CRS-300 1:10 Redundancy Switch Revision 16 Front Panel Operation MN/CRS300.IOM 7–16 The three-letter instruction code is indicated also to assist de

Pagina 109

CRS-300 1:10 Redundancy Switch Revision 16 Front Panel Operation MN/CRS300.IOM 7–17 ► For the CDM-Qx modem, the code is the decimal number indicati

Pagina 110

CRS-300 1:10 Redundancy Switch Revision 16 Front Panel Operation MN/CRS300.IOM 7–18 7.6.3 MONITOR: STORED-EVENTS STORED EVENTS: VIEW CLEAR-ALL (

Pagina 111

CRS-300 1:10 Redundancy Switch Revision 16 Front Panel Operation MN/CRS300.IOM 7–19 7.7 SELECT: STORE/LD (Store or Load Configuration) STORE/LOAD

Pagina 113

CRS-300 1:10 Redundancy Switch Revision 16 Preface MN/CRS300.IOM xviii Warranty Policy Comtech EF Data products are warranted against defects in mat

Pagina 114

CRS-300 1:10 Redundancy Switch Revision 16 Front Panel Operation MN/CRS300.IOM 7–20 7.8 SELECT: UTILITY UTILITY: SET-RTC DISPLAY SWITCH-ID TE

Pagina 115

CRS-300 1:10 Redundancy Switch Revision 16 Front Panel Operation MN/CRS300.IOM 7–21 7.8.4 UTILITY: TEST This is an excellent method to test the wh

Pagina 116

CRS-300 1:10 Redundancy Switch Revision 16 Front Panel Operation MN/CRS300.IOM 7–22 Notes:

Pagina 117

A-1 Appendix A. CABLE DRAWINGS A.1 Introduction This appendix contains drawings of cables used with the CRS-300. These cables are divided into thre

Pagina 118

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-2 A.2.1 EIA-530 to EIA-422 Data Cable Figure A-1 shows the cable drawing

Pagina 119

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-3 A.2.2 EIA-530 to V.35 Data Cable Figure A-2 shows the cable drawing fo

Pagina 120

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-4 A.2.3 Switch Programming Cable Figure A-3 shows the cable required for

Pagina 121

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-5 A.3 Control Cables App. A FIG CEFD P/N DESCRIPTION USED WITH CRS

Pagina 122

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-6 A.3.1 Control Cable for CDM-625 Figure A-4 shows the control cable that

Pagina 123

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-7 A.3.2 Standard EIA-485 Multi-drop Shielded Cable, (15X) DB-9 Female Fig

Pagina 124

CRS-300 1:10 Redundancy Switch Revision 16 Preface MN/CRS300.IOM xix The warranty excludes any responsibility by Comtech EF Data Corporation for inc

Pagina 125

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-8 A.3.3 EIA-485 Cable Termination, (15X) DB-9 Male Figure A-6 shows the E

Pagina 126

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-9 A.3.4 EIA-485 Null Modem Cable, DB-9 Male Figure A-7 shows the EIA-485

Pagina 127 - NETWORK CONFIGURATIONS

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-10 A.3.5 Optional EIA-485 Multi-drop Ribbon Cable, (15X) DB-9 Female Figu

Pagina 128

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-11 A.3.6 Control ‘Y’ Cable for CDM-Qx and CDM-QxL with CnC® Figure A-9 sh

Pagina 129

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-12 A.3.7 Control Cable for CDM-700, CDM-710 Figure A-10 shows the control

Pagina 130

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-13 A.3.8 Control Cable for SLM-5650/5650A Figure A-11 shows the control c

Pagina 131

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-14 A.3.9 Control ‘Y’ Cable for SLM-5650/5650A to CRS-300 Figure A-12 show

Pagina 132

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-15 A.4 Control / IF / Data Cables & Accessories App. A FIG CEFD P/N

Pagina 133 - IMPORTANT

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-16 App. A FIG CEFD P/N DESCRIPTION USED WITH CRS-300 Æ … Chp. 4 FIG USE

Pagina 134

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-17 A.4.1 EIA-232/422, EIA-530 Control and Data Cable, DB-25 Figure A-13 s

Pagina 135

CRS-300 1:10 Redundancy Switch Revision 16 Preface MN/CRS300.IOM xx Customer Support IMPORTANT Refer to the Warranty Policy, p. xviii, for informati

Pagina 136

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-18 A.4.2 Balanced G.703 Data Cable for CDM-570/570L, DB-15 Figure A-14 sh

Pagina 137

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-19 A.4.3 Balanced G.703 Data Cable, DB-15 Figure A-15 shows the data cabl

Pagina 138

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-20 A.4.4 Audio Data Cable, DB-9 Figure A-16 shows the cable used for hand

Pagina 139 - 4.11 IF Cable Connections

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-21 A.4.5 Balanced G.703 Data Cable for CDM-625 Figure A-17 shows the cabl

Pagina 140 - 4.11 IF Cable Connections

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-22 A.4.6 Quad E1 ‘Y’ Data Cable for CDM-625 Figure A-18 shows the cable a

Pagina 141

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-23 A.4.7 ASI / Balanced G.703 / IF Cable, BNC 75Ω Figure A-19 shows the 7

Pagina 142

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-24 A.4.8 Overhead Data Cable for CDM-625 Figure A-20 shows the multi-purp

Pagina 143

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-25 A.4.9 HSSI Data Cable, HD-50 Male Figure A-21 shows the HSSI data cabl

Pagina 144

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-26 A.4.10 Quad E1 Data Cable for CDM-Qx / QxL Figure A-22 shows the cable

Pagina 145 - IMPOR TANT

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-27 A.4.11 Quad E1 / Gigabit Ethernet RJ-48 Connector Cable Figure A-23 sh

Pagina 146 - 5.2.2.1 Flash Updating

1–1 Chapter 1. INTRODUCTION 1.1 Overview This chapter provides an overview, description and specifications for the CRS-300 1:10 Redundancy Switch and

Pagina 147

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-28 A.4.12 G.703 Data Cable for CDM-700 Figure A-24 shows the cable used t

Pagina 148

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-29 A.4.13 G.703 Data Cable for CDM-700 Figure A-25 shows the cable used t

Pagina 149

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-30 A.4.14 IF Cable, BNC 50Ω Figure A-26 shows the 50Ω BNC cable used for

Pagina 150 - Processor (NP) Interface

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-31 A.4.15 Ethernet Data Cable for CDM-625 Figure A-27 shows the Ethernet

Pagina 151

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-32 A.4.16 Multi-drop CnC® Plus Shielded Data Cable for CDM-625, (11X) D

Pagina 152 - Slot 4 Demod

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-33 A.4.17 Quad E1 Data Cable for CDM-625, DB-9 Figure A-29 shows the DB-9

Pagina 153

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-34 A.4.18 Quad E1 Data Adapter Cable for CDM-625 Figure A-30 shows the d

Pagina 154

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-35 A.4.19 Quad E1 Data Adapter Cable for CDM-625 Figure A-31 shows the d

Pagina 155 - Tables 5-2 throu

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-36 A.4.20 T1/E1 Adapter for CDM-570/570L, -600/600L Figure A-32 shows the

Pagina 156

B–1 Appendix B. ADDRESSING SCHEME INFORMATION B.1 Introduction to Addressing A CRS-300 1:10 Redundancy Switch provides 1:10 redundancy; that is, it

Pagina 157

CRS-300 1:10 Redundancy Switch Revision 16 Introduction MN/CRS300.IOM 1–2 The CRS-300 1:10 Redundancy Switch (referred to throughout this manual as

Pagina 158 - Rev. D and later versions

CRS-300 1:10 Redundancy Switch Revision 16 Addressing Scheme Information MN/CRS300.IOM B–2 B.2 Switch Addresses The permitted Switch remote control

Pagina 159

CRS-300 1:10 Redundancy Switch Revision 16 Addressing Scheme Information MN/CRS300.IOM B–3 Figure B-1. CRS-300 Addressing Scheme Example: Exter

Pagina 160

CRS-300 1:10 Redundancy Switch Revision 16 Addressing Scheme Information MN/CRS300.IOM B–4 Figure B-2. CRS-300 Addressing Scheme Example: Externa

Pagina 161 - CA and TA

CRS-300 1:10 Redundancy Switch Revision 16 Addressing Scheme Information MN/CRS300.IOM B–5 Figure B-3. CRS-300 Addressing Scheme E

Pagina 162 - 5.5.1 Switch Power

CRS-300 1:10 Redundancy Switch Revision 16 Addressing Scheme Information MN/CRS300.IOM B–6 Figure B-4. CRS-300 Addres

Pagina 163 - 5.5.2 Flash Updating

CRS-300 1:10 Redundancy Switch Revision 16 Addressing Scheme Information MN/CRS300.IOM B–7 Figure B-5. CRS-300 Addres

Pagina 164

CRS-300 1:10 Redundancy Switch Revision 16 Addressing Scheme Information MN/CRS300.IOM B–8 Figure B-6. CRS-300 Ad

Pagina 165 - 5.5.2.1.1 Flash Update Help

CRS-300 1:10 Redundancy Switch Revision 16 Addressing Scheme Information MN/CRS300.IOM B–9 Figure B-7. CRS-300 Addressing Scheme E

Pagina 166

CRS-300 1:10 Redundancy Switch Revision 16 Addressing Scheme Information MN/CRS300.IOM B–10 This page is intentionally blank.

Pagina 167 - 5.5.3.4 Set Holdoff Period

CRS-300 1:10 Redundancy Switch Revision 16 Addressing Scheme Information MN/CRS300.IOM B–11 B.3.1 Setting Up Modems • Local Modem m, wher

Pagina 168 - 5.5.3.5 Set Alarm Masking

CRS-300 1:10 Redundancy Switch Revision 16 Introduction MN/CRS300.IOM 1–3 NOTE the CRS-300). For detailed information on remote addressing sch

Pagina 169

CRS-300 1:10 Redundancy Switch Revision 16 Addressing Scheme Information MN/CRS300.IOM B–12 B.3.2 Setting Up Transceivers IMPORTANT Config

Pagina 170

C–1 Appendix C. REMOTE CONTROL C.1 Overview This appendix describes the protocol and message command set for remote monitor and control of the CRS

Pagina 171

CRS-300 1:10 Redundancy Switch Revision 16 Remote Control MN/CRS300.IOM C–2 C.3 EIA-232 This is a much simpler configuration in which the Controlle

Pagina 172

CRS-300 1:10 Redundancy Switch Revision 16 Remote Control MN/CRS300.IOM C–3 o To a local BUC or transceiver connected to a local modem; o To a dis

Pagina 173

CRS-300 1:10 Redundancy Switch Revision 16 Remote Control MN/CRS300.IOM C–4 modem protocol and the installed options. Consult the appropriate modem

Pagina 174 - ASI connectors

CRS-300 1:10 Redundancy Switch Revision 16 Remote Control MN/CRS300.IOM C–5 C.5.5 Instruction Code Qualifier This single character further qualifie

Pagina 175

CRS-300 1:10 Redundancy Switch Revision 16 Remote Control MN/CRS300.IOM C–6 C.5.6 Optional Message Arguments Arguments are not required for all mes

Pagina 176 - Unbalanced G.703 connectors

CRS-300 1:10 Redundancy Switch Revision 16 Remote Control MN/CRS300.IOM C–7 Parameter Type Command (Code and qualifier) Arguments for Command or Re

Pagina 177

CRS-300 1:10 Redundancy Switch Revision 16 Remote Control MN/CRS300.IOM C–8 Parameter Type Command (Code and qualifier) Arguments for Command or Res

Pagina 178

CRS-300 1:10 Redundancy Switch Revision 16 Remote Control MN/CRS300.IOM C–9 Parameter Type Command (Code and qualifier) Arguments for Command or Res

Pagina 179 - Quad E1 connectors

CRS-300 1:10 Redundancy Switch Revision 16 Introduction MN/CRS300.IOM 1–4 1.2 CRS-300 Compatibility Table 1-1 shows the Comtech EF Data modems tha

Pagina 180

CRS-300 1:10 Redundancy Switch Revision 16 Remote Control MN/CRS300.IOM C–10 Parameter Type Command (Code and qualifier) Arguments for Command or Re

Pagina 181 - OPERATION

CRS-300 1:10 Redundancy Switch Revision 16 Remote Control MN/CRS300.IOM C–11 Parameter Type Command (Code and qualifier) Arguments for Command or Re

Pagina 182

CRS-300 1:10 Redundancy Switch Revision 16 Remote Control MN/CRS300.IOM C–12 Parameter Type Command (Code and qualifier) Arguments for Command or Re

Pagina 183

CRS-300 1:10 Redundancy Switch Revision 16 Remote Control MN/CRS300.IOM C–13 Parameter Type Command (Code and qualifier) Arguments for Command or Re

Pagina 184

CRS-300 1:10 Redundancy Switch Revision 16 Remote Control MN/CRS300.IOM C–14 Parameter Type Command (Code and qualifier) Arguments for Command or Re

Pagina 185 - 7.1.4 Opening Screen

METRIC CONVERSIONS Units of Length Unit Centimeter Inch Foot Yard Mile Meter Kilometer Millimeter 1 centimeter — 0.3937 0.03281 0.01094

Pagina 186 - 7.2 CRS-300 Menu Structure

2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 • 333 • 2200 PHONE 480 • 333 • 2161 FAX

Pagina 187

CRS-300 1:10 Redundancy Switch Revision 16 Introduction MN/CRS300.IOM 1–5 1.3 System-Level Block Diagram Figure 1-1 shows the system-level block d

Pagina 188 - 7.4.1 CONFIG: MANUAL

CRS-300 1:10 Redundancy Switch Revision 16 Introduction MN/CRS300.IOM 1–6 1.3.1 CRS-280/280L Functional Schematic Figure 1-2 provides an operatio

Pagina 189 - 7.4.3 CONFIG: OPTIONS

CRS-300 1:10 Redundancy Switch Revision 16 Introduction MN/CRS300.IOM 1–7 1.4 Description of CRS-300 Features 1.4.1 Front Panel Figure 1-3 illust

Pagina 190

Copyright © Comtech EF Data, 2010. All rights reserved. Printed in the USA. Comtech EF Data, 2114 West 7th Street, Tempe, Arizona 85281 USA, 480.333.

Pagina 191 - 7.4.4 CONFIG: REMOTE

CRS-300 1:10 Redundancy Switch Revision 16 Introduction MN/CRS300.IOM 1–8 NOTE 1.4.2 Rear Panel Figure 1-4 shows the back panel of the CRS-30

Pagina 192

CRS-300 1:10 Redundancy Switch Revision 16 Introduction MN/CRS300.IOM 1–9 CDM-625 Modem Data Type TMI Type RMI Type EIA-422, V.35 CRS-316 Notes 5

Pagina 193 - 7.5.4 INFO: IF-SWITCH

CRS-300 1:10 Redundancy Switch Revision 16 Introduction MN/CRS300.IOM 1–10 1.4.3.2 TMI Cards: CDM-570/570L, -600/600L, -625 Figure 1-6. CRS-320 TM

Pagina 194 - 7.6.1 MONITOR: STATUS

CRS-300 1:10 Redundancy Switch Revision 16 Introduction MN/CRS300.IOM 1–11 1.4.4 Modem Interface Cards: CDM-Qx/QxL, -700, -710, -710G, SLM-5650/56

Pagina 195 - 7.6.2 MONITOR: SW-ALARM

CRS-300 1:10 Redundancy Switch Revision 16 Introduction MN/CRS300.IOM 1–12 1.4.4.1 RMI Cards: CDM-Qx/QxL, -700, -710, -710G, SLM-5650/5650A Figure

Pagina 196

CRS-300 1:10 Redundancy Switch Revision 16 Introduction MN/CRS300.IOM 1–13 1.4.4.2 TMI Cards: CDM-Qx/QxL, -700, -710, -710G, SLM-5650/5650A Figure

Pagina 197

CRS-300 1:10 Redundancy Switch Revision 16 Introduction MN/CRS300.IOM 1–14 1.4.5 CRS-300 System Controller and Power Supply Card Assembli

Pagina 198 - 7.6.5 MONITOR: IO

CRS-300 1:10 Redundancy Switch Revision 16 Introduction MN/CRS300.IOM 1–15 Figure 1-24. CRS-350 ESC Switch – Front Panel As explained in detail in

Pagina 199 - 7.7.2 STORE/LD: LOAD

CRS-300 1:10 Redundancy Switch Revision 16 Introduction MN/CRS300.IOM 1–16 1.6 Summary of Specifications 1.6.1 CRS-300 Specifications Characteris

Pagina 200 - 7.8.3 UTILITY: SWITCH-ID

CRS-300 1:10 Redundancy Switch Revision 16 Introduction MN/CRS300.IOM 1–17 1.6.2 Modem vs. Terrestrial User Data Interface Specifications Modem T

Pagina 201 - 7.8.5 UTILITY: RELAY

This page is intentionally blank.

Pagina 202

CRS-300 1:10 Redundancy Switch Revision 16 Introduction MN/CRS300.IOM 1–18 1.6.3 CRS-280 and CRS-280L Specifications Characteristic Requirement C

Pagina 203 - Appendix A. CABLE DRAWINGS

CRS-300 1:10 Redundancy Switch Revision 16 Introduction MN/CRS300.IOM 1–19 11.94 (30.3) 17.00 (43.2) 12.68 (322) CLR ENT UNIT STATUSUNIT STATUS UN

Pagina 204

CRS-300 1:10 Redundancy Switch Revision 16 Introduction MN/CRS300.IOM 1–20 Figure 1-29. CRS-280 (70/140 MHz) Dimensional Envelope

Pagina 205

CRS-300 1:10 Redundancy Switch Revision 16 Introduction MN/CRS300.IOM 1–21 17.00(43.18)13.18(33.48)13.92(35.36)6.96(17.68)19.00(48.26) Figure 1-30.

Pagina 206

CRS-300 1:10 Redundancy Switch Revision 16 Introduction MN/CRS300.IOM 1–22 Notes:

Pagina 207 - A.3 Control Cables

2–1 Chapter 2. INSTALLATION 2.1 Unpacking and Inspection Step Procedure 1 Inspect shipping containers for damage. 2 If shipping containers are damag

Pagina 208

CRS-300 1:10 Redundancy Switch Revision 16 Installation MN/CRS300.IOM 2–2 or on top of the rack. If using the CRS-280L, refer also to the associate

Pagina 209

3–1 Chapter 3. ETHERNET NETWORK CONFIGURATIONS 3.1 Introduction For operations requiring Ethernet-based terrestrial data handling, it is important t

Pagina 210

CRS-300 1:10 Redundancy Switch Revision 16 Ethernet Network Configurations MN/CRS300.IOM 3–2 3.3 Ethernet Configuration Examples This section exp

Pagina 211

CRS-300 1:10 Redundancy Switch Revision 16 Ethernet Network Configurations MN/CRS300.IOM 3–3 3.3.2 Ethernet Redundancy with CRS-300 After the cus

Pagina 212

iii Table of Contents TABLE OF CONTENTS ...

Pagina 213

CRS-300 1:10 Redundancy Switch Revision 16 Ethernet Network Configurations MN/CRS300.IOM 3–4 3.3.3 Hub-to-Hub with Standard Traffic using Switche

Pagina 214

CRS-300 1:10 Redundancy Switch Revision 16 Ethernet Network Configurations MN/CRS300.IOM 3–5 This page is intentionally blank

Pagina 215

CRS-300 1:10 Redundancy Switch Revision 16 Ethernet Network Configurations MN/CRS300.IOM 3–6 3.3.4 Hub-to-Hub with Standard Traffic using Routers F

Pagina 216

CRS-300 1:10 Redundancy Switch Revision 16 Ethernet Network Configurations MN/CRS300.IOM 3–7 Figure 3-5. Wired-thru for Hub-to-Hub with Standard Tr

Pagina 217

CRS-300 1:10 Redundancy Switch Revision 16 Ethernet Network Configurations MN/CRS300.IOM 3–8 3.3.5 Hub-to-Remotes with Standard Traffic using Route

Pagina 218 - Chp. 4 FIG USED FOR (TYPE)

CRS-300 1:10 Redundancy Switch Revision 16 Ethernet Network Configurations MN/CRS300.IOM 3–9 Figure 3-8. Wired-thru for Hub-to-Remotes with Standar

Pagina 219

CRS-300 1:10 Redundancy Switch Revision 16 Ethernet Network Configurations MN/CRS300.IOM 3–10 3.3.6 Hub-to-Remotes, Split-path Traffic using Router

Pagina 220

CRS-300 1:10 Redundancy Switch Revision 16 Ethernet Network Configurations MN/CRS300.IOM 3–11 Figure 3-11. Wired-thru for Point-to-Multipoint wit

Pagina 221

CRS-300 1:10 Redundancy Switch Revision 16 Ethernet Network Configurations MN/CRS300.IOM 3–12 3.3.7 Hub-to-Remotes, Split-path Traffic using Switch

Pagina 222

CRS-300 1:10 Redundancy Switch Revision 16 Ethernet Network Configurations MN/CRS300.IOM 3–13 Figure 3-14. Wired-thru, Hub-to-Remotes, Split-path T

Pagina 223

CRS-300 1:10 Redundancy Switch Revision 16 Table of Contents MN/CRS300.IOM iv 1.4 Description of CRS-300 Features ...

Pagina 224

CRS-300 1:10 Redundancy Switch Revision 16 Ethernet Network Configurations MN/CRS300.IOM 3–14 Notes:

Pagina 225

4–1 Chapter 4. CABLES AND CONNECTIONS 4.1 Overview All cables for connecting the CRS-300 1:10 Redundancy Switch to the modems or within the

Pagina 226

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–2 Notes:

Pagina 227

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–3 4.2 Switch-to-Switch Connections o CRS-300 to CR

Pagina 228

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–4 4.2 Switch-to-Switch Connections If the User’s redundancy syst

Pagina 229

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–5 Figure 4-1. Control Cable Connection Example for CRS-300

Pagina 230 - CDM-700 Modem Connections

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–6 Figure 4-2. Control Cable Connection Example for CRS-300

Pagina 231

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–7 Figure 4-3. Control Cable Connection Example for CRS-300

Pagina 232 - A.4.14 IF Cable, BNC 50Ω

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–8 Figure 4-4. Control Cable Connection Example for CRS-300 Æ CR

Pagina 233

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–9 Figure 4-5. Control Cable Connection Example for CRS-300 Æ CRS

Pagina 234 - A.4.16 Multi-drop CnC

CRS-300 1:10 Redundancy Switch Revision 16 Table of Contents MN/CRS300.IOM v 4.2.2 CRS-300 to CRS-350 Connection ...

Pagina 235

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–10 Notes:

Pagina 236

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–11 4.3 CDM-570/570L Modem Connections o Co

Pagina 237

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–12 4.3 CDM-570/570L Modem Connections If adding a modem to an op

Pagina 238

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–13 Figure 4-6. Data Cable Connection Example – CRS-300 to CDM-5

Pagina 239 - SCHEME INFORMATION

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–14 Notes:

Pagina 240 - B.2 Switch Addresses

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–15 4.4 CDM-600/600L Modem Connections o Contro

Pagina 241

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–16 4.4 CDM-600/600L Modem Connections If adding a modem to an op

Pagina 242

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–17 Figure 4-7. Data Cable Connection Example – CRS-300 to CDM-6

Pagina 243 - 1.6.2 or later

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–18 4.4.2 User Data Connections – CRS-300 to User The User’s tra

Pagina 244

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–19 Figure 4-8. Cabling Example for CRS-350 to CDM-600/60

Pagina 245

CRS-300 1:10 Redundancy Switch Revision 16 Table of Contents MN/CRS300.IOM vi 4.7.5.2 Wired-around Connections ...

Pagina 246

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–20 Notes:

Pagina 247

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–21 4.5 CDM-625 Modem Connections o RMI/TMI Limita

Pagina 248

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–22 4.5 CDM-625 Modem Connections If adding a modem to an operati

Pagina 249 - B.3.1 Setting Up Modems

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–23 Figure 4-9. CDM-625 to CDM-625 CnC® Cable Connection Exampl

Pagina 250 - B.4 M&C Applications

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–24 4.5.3 Control and Data Connections – CRS-300 to Modem Table 4

Pagina 251 - Appendix C. REMOTE CONTROL

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–25 For specific details regarding the CA/WR0066 cable’s use as a

Pagina 252 - C.4 Basic Protocol

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–26 • DB-9F connector labeled “1:1 Control” on the Traffic CDM-62

Pagina 253 - C.5.2 Target Address

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–27 4.5.3.4 EIA-422 Data Connections If EIA-422 is the driving t

Pagina 254 - C.5.4 Instruction Code

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–28 Then, connect and secure the Control/Data Cable CA/WR0066 (for

Pagina 255

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–29 4.5.3.8 Ethernet Data Connections IMPORTANT1. When using the

Pagina 256 - C.5.7 End of Packet

CRS-300 1:10 Redundancy Switch Revision 16 Table of Contents MN/CRS300.IOM vii 5.4 TMI Card Configuration Reference ...

Pagina 257

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–30 NO TE 1. Where the traffic data type is Ethernet, the User c

Pagina 258

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–31 Figure 4-10. CRS-300 to CDM-

Pagina 259

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–32 Figure 4-11. CRS-300 to CDM-625 Cable Connection Example – G.

Pagina 260

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–33 Figure 4-12. C

Pagina 261

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–34 Figure 4-13. C

Pagina 262

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–35 4.5.4 Data Connections – CRS-300 to User The User’s traffic

Pagina 263

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–36 The choices from this display are: • Normal: CDM-625 • Emula

Pagina 264

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–37 Figure 4-15. Data Cables - CRS-300 to CDM-625 (CDM-600/600L E

Pagina 265

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–38 Notes:

Pagina 266 - • 333 • 2161 FAX

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–39 4.6 CDM-Qx/QxL Modem Connections o RMI/TMI Lim