Comtech EF Data UT-4518E Especificaciones Pagina 93

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 132
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 92
UT-4500-A Series Upconverters Revision 0
Appendix A MN-UT4500A
A–7
A.7 Command / Response Pairs
A.7.1 Utility Commands
A.7.1.1 Time
Command Details
Set Time: <DEV/TIM_hh:mm:ss'cr'
Where:
hh=Hour
mm=Minutes
ss=Seconds
Confirmation: >DEV/TIM_hh:mm:ss'cr''lf']
Retrieve Time: <DEV/TIM_'cr'
Confirmation: >DEV/TIM_hh:mm:ss'cr''lf']
A.7.1.2 Date
Command Details
Set Date: <DEV/DAT_mm/dd/yy'cr’
Where:
mm=Month
dd=Day
yy=Year
Confirmation: >DEV/DAT_mm/dd/yy'cr'lf']
Retrieve Date: <DEV/DAT_'cr'
Confirmation: >DEV/DAT_mm/dd/yy'cr''lf']
A.7.1.3 Local / Remote Status
The LRS command is used to enable or disable remote communications interfaces. The factory default
setting is 3 (Ethernet and Serial remote control enabled).
Command Details
Set Local / Remote
Status:
<DEV/LRS_x'cr’
Where:
x=
0 for front panel control only (remote control disabled)
1 for serial remote control
2 for Ethernet control
3 for Ethernet and serial remote control
Confirmation: >DEV/LRS_x'cr'lf']
Retrieve LRS: <DEV/LRS_'cr'
Confirmation: >DEV/LRS_x'cr''lf']