CiM-25/600 IP Enabled M&C Rev. 3
SNMP Interface CD/CIM25600.IOM
43
3.6.1 RESETTING TO FACTORY DEFAULTS
1
Enter the following command:
Command: <0/RST=’cr’
Response: >0/RST=
3.6.2 CHANGING NETWORK IP ADDRESS
Perform the following steps.
1
Enter the following command:
Command: <0/IPA=xxx.xxx.xxx.xxx/yy’cr’
Where x is the IP Address and y is the subnet mask.
Response: >0/IPA=
Example: <0/IPA=192.168.001.002/16’cr’
16 would be a subnet mask of 255.255.0.0
2
To query the IP address enter: <0/IPA?’cr’
3.6.3 VERIFYING SOFTWARE VERSION
Perform the following:
1
Enter the following command:
Command: <0/SWR?’cr’
Response: >0/SWR= 1.0.1’cr’
3.6.4 CHANGING MAC ADDRESS
Perform the following:
1
Enter the following command:
Command: <0/MAC=xxxxxxxxx’cr’
Where x is the MAC Address as shown on the label of the CiM-25.
Response: >0/MAC=
Example: >0/MAC=006B0000000A’cr’
2
To query the MAC Address enter: >0/MAC?’cr’
IMPORTANT
1. The MAC Address is unique to this unit. Change only under factory
direction or if it does not match the label.
2. Changing the MAC Address to anything other than factory default may
result in erratic operation.