Comtech EF Data KST-2000B Especificaciones Pagina 35

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 184
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 34
CiM-25/600 IP Enabled M&C Rev. 3
SNMP Interface CD/CIM25600.IOM
17
3.3.5.2 READ/WRITE NAME AND PASSWORD
The factory defaults for these parameters are opcenter and 1234 respectively. The Name
field can be any alpha-numeric combination with a minimum length of 4 characters and a
maximum length of 10 characters. The Password field can be any alpha-numeric
combination with a minimum length of 4 characters and a maximum length of 10
characters.
3.3.5.3 READ ONLY NAME AND PASSWORD
The factory defaults for these parameters are monitor and 1234 respectively. The Name
field can be any alpha-numeric combination with a minimum length of 4 characters and a
maximum length of 10 characters. The Password field can be any alpha-numeric
combination with a minimum length of 4 characters and a maximum length of 10
characters.
3.3.5.4 HOST ALLOW LIST
The Host Allow List can be configured as any of the following combinations:
1 to 6 individual IP addresses.
1 to 3 ranges of IP addresses.
A combination of individual and range addresses.
The Administrator simply checks the Range Yes radio button next to the group of two IP
addresses that constitute the beginning and ending of the range.
3.3.5.5 PING ENABLE / DISABLE
The factory defaults for this parameter is Enabled. The radio buttons allow the
Administrator to choose between Enabled and Disabled.
3.3.5.6 CiM-25 IP ADDRESS, GATEWAY AND MASK
The factory defaults for these parameters are 10.6.30.1, 0.0.0.0, and 255.255.0.0
respectively. The Administrator can change these as required.
3.3.5.7 DNS SERVERS
The Administrator can assign both a primary and secondary DNS server IP address.