CiM-25/600 IP Enabled M&C Rev. 3
SNMP Interface CD/CIM25600.IOM
38
3.5.1.8 CHANGE READ ONLY PASSWORD
Using the !RP command, the Administrator can change the Read/Only login Password.
The command protocol is as follows:
Format: !RP <string>
Where: <string> can be any alphanumeric string of 4 to 10 characters in length
Query Format: !RP ?
Response: !RP <string>
Note:
Changes made via this command do not become active until the user has sent a !EE
command to commit the changes to EEPROM of the CiM-25.
3.5.1.9 ENABLE OR DISABLE PING
Using the !PG command, the Administrator can either enable or disable PING. The
command protocol is as follows:
Format: !PG <state>
Where: 0 = Disabled, 1 = Enabled
Query Format: !PG ?
Response: !PG <state>
Note:
Changes made via this command do not become active until the user has sent a !EE
command to commit the changes to EEPROM of the CiM-25.
3.5.1.10 COMMIT CHANGES TO EEPROM
Using the !EE command, the Administrator can commit any previously commanded
changes to EEPROM. This will store the new operating parameters and automatically do
a warm reboot of the CiM-25/600. The command protocol is as follows:
Format: !EE