Vista de pagina 238
CDD-562L/564 Demodulator with IP Module Revision 2
Appendix D MN/CDD564L.IOM
D–23
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
IP Software
Information
None String Query only.
Complete IP software information:
Example: FRW=
System time is THU DEC 22 14:53:50 2005
Booted using image #1
Using configuration parameters from PARAM #
IFW!
IFW?
IFW =x….x
(see Description of Arguments)
Type Date
Time
Name
Rev
Len
Boot
IP Bulk#1
IP Bulk #2
EVENT LOG
PARAM
BaseBoot
BaseBulk#1
BaseBulk#2
1/24/2006
12/27/2005
12/14/2005
02/01/2006
1/26/2006
03/30/2004
01/26/2006
01/04/2006
15:26
17:27
14:19
14:10
18:29
-- --
-- --
-- --
FW/10873-1c
5.3 Pre
5.3 Pre
eventlog
console
FW/10804-1-
FW/10805T
FW/10805R
1.1.3
1.5.3
1.5.3
1.5.3
1.5.3
1.1.1
1.5.1N
1.5.1g
460804
chr(13)
2607240
chr(13)
2604308
chr(13)
128000
chr(13)
5160
chr(13)
----
chr(13)
----
chr(13)
----
chr(13)
chr(10)
Restore Factory
Defaults
RFD 1-Byte value
1 – restore
Command only.
Set to ‘1’ to bring the modem back to factory defaults. This may force unit reboot,
depending on the mode of operation.
RFD=
RFD!
N/
A
RFD=x
(see Description of Arguments)
Reset Unit RST 1 byte value.
1 – reset system
Command only.
Set to ‘1’ to reset the system. Telnet2 connection needs to be re-established.
RST=
RST!
N/
A
RST=x
(see Description of Arguments)