CDD-562L/564 Demodulator with IP Module Revision 2
CDD-56X CLI and Telnet Operation MN/CDD564L.IOM
8–53
8.2.8.3 Database Operations page
Access the Database Operations page from the Operations and Maintenance page.
The User Configuration File allows overwrite of the values defined in the Factory Configuration
File. The demodulator uses these files to initialize itself on power-up. The use of the User
Configuration File allows full customization of a demodulator without erasing the factory-defined
operating parameters. This file also can be retrieved or overwritten via FTP by specifying the
filename ‘param1’.
Use this page to view, save, or erase an existing User Configuration File for the demodulator.
This page contains the following unique selections/fields:
Selection Entry Description
Restore Factory Default R Restores the demodulator settings to “safe” values as defined by
the factory.
Load Parameters from permanent
storage
P Overwrites the current configuration of the demodulator with the
configuration last saved to permanent storage. Allows user to
perform an “Undo” type operation if the demodulator is put into an
undesirable state by the user [provided the undesired configuration
is not saved.].