DMD2050E Universal Satellite Modem TCP/IP Ethernet Setup
MN-DMD2050E Revision 2 F–3
and loop back addresses will not be allowed. Example Server IP Address setting:
172.018.004.250.
7.
ROUTER IP ADDR: This allows for the setup of the Network Router IP Address. If a router is
present on the local network, and it is to be used, this address must be consistent with the IP
Address Mask and the subnet of the modem. If no router is present, then the address should be
set to a foreign address. Broadcast and loop back addresses will not be allowed. Router not
used example: Router IP Address setting: 010.000.001.001.
8.
MODEM EADDR: This displays the Modem (Unit) Ethernet Address. The Modem Ethernet
Address is configured at the factory. It is a unique Radyne equipment identifier Address.
Example: 0010650903EB
9.
ETHER RATE: This displays the current Ethernet port data rate. If multiple rates are available,
then a selection can be made to specify the Ethernet port data rate (10BaseT). Example
Ethernet port Data Rate: 10 MBPS/HD
F.3 Network Configuration Summary
If the above steps were followed and the information was entered, then the following would be the
TCP / IP configuration summary for a ‘no router specified’ setup:
1. Boot Mode = NON-VOL
2. Bootp Server Tag = 206
3. Modem Host= DMD20
4. IP Address Mask = 255.255.0.0
5. Modem IP Address = 172.18.100.215
6. Server IP Address = 172.18.4.250
7. Router IP Address = 010.000.001.001
8. Modem Ethernet Address= 0010650903EB
9. Ethernet Rate = 10 MBPS/HD