DMD2050E Universal Satellite Modem User Interfaces
MN-DMD2050E Revision 2 4–39
For numerical input, use the number keys to input the data. Press ENTER to save the data.
To cancel numerical input before you save it, press ESC.
NOTE
Using an invalid input key causes the terminal to show an error message.
4.5.3 Setup for Terminal Mode
NOTE
When you use the terminal for the first time, use the $ (dollar) character to reset the
memory.
1. Connect the RS-232 cable between the terminal device and the REMOTE J20 connector
on the rear of the unit.
2. Set up Terminal Mode Communications and Protocol from the front panel of the unit.
a. Set the
System > Remote Control Mode parameter to Terminal.
b. Set the
System > Terminal > Baud Rate parameters as necessary:
Select from serial baud rates of 150, 300, 1200, 2400, 4800, 9600, 19200,
38400, 57600 or 115200
3. Set the
System > Terminal > Type.
Select from the three emulation types:
VT100, WYSE50, VIEWPOINT
Set terminal parameters to (
8, N, 1):
8 data bits
No parity
1 stop bit
If using a computer as a terminal, set emulation to
VT100. Use HyperTerminal or ProComm on
the computer.