Vista de pagina 120
CRS-170A L-Band 1:1 Redundancy Switch MN/CRS170A.IOM
Cables and Connections Revision 13
5–51
5.8.1.2 Modem-to-Switch IF Interface Connection
Excluding the modems, the KT/12551 CRS-170A L-Band 1:1 Redundancy Kit (see
Sect. 5.8.1) provides all components shown in Figure 5-41.
EXAMPLE: The Tx IF from ‘MODEM A’ connects to the Tx IF port ‘J5 | Tx A’ on the
CRS-170A; similarly, the Tx IF from ‘MODEM Bconnects to the Tx IF port ‘J6 | Tx B’
on the CRS-170A.
The same logic applies for the Rx IF connections. It is important to note that failure
to observe this requirement will result in system malfunction.
CEFD Part No. Qty Description
CA/RF10453-4 4 RoHS-Compliant Cable IF (Tx/Rx), 50Type ‘N’, 4’
Figure 5-41. CDM-710GL Modem-to-Switch L-Band IF Connections