CDM-710G High-Speed Satellite Modem Revision 1
Front Panel Operation MN-CDM710G
6–39
If Intfc1 Port1 Tx Alarms: Æ Buffer-Slip is selected:
Buffer Slip Alarm:
Alarm Fault Mask ( E)
The default selection is Alarm. Select Alarm, Fault, or Mask using the arrow keys, then
press
ENTER.
If Intfc1 E3T3STS1 Alarms: Æ Ext-Clk is selected:
Intfc1 Ext-Clk Alarm:
Alarm Fault Mask ( E)
The default selection is Alarm. To configure the loss of External Clock as either an Alarm or a
Fault condition or to mask the alarm, select Alarm, Fault, or Mask using the
arrow keys,
then press
ENTER.
(CONFIG:) Alarm Mask: Æ Intfc1 (CDI-60 HSSI Interface Card)
Intfc1 HSSI Alarms:
Tx Rx ( E)
Select Tx or Rx using the arrow keys, then press ENTER.
If Intfc1 HSSI Alarms: Æ Tx is selected:
Intfc1 Tx Clock Alarm:
Alarm Fault Mask ( E)
Select Alarm, Fault, or Mask using the arrow keys, then press ENTER. The default
selection is Alarm.
If Intfc1 HSSI Alarms: Æ Rx is selected:
Buffer Slip Alarm:
Alarm Fault Mask ( E)
Select Alarm, Fault, or Mask using the arrow keys, then press ENTER. The default
selection is Alarm.
(CONFIG:) Alarm Mask: Æ Intfc2 (CDI-70 GigE Interface Card)
GBEI Tx Cable Alarm:
Alarm Fault Mask ( E)
Select Alarm, Fault, or Mask using the arrow keys, then press ENTER. The default
selection is Alarm.