LPOD C-, X-, or Ku-Band Outdoor Amplifier / Block Up Converter (BUC) MN-LPOD
Serial-based Remote Product Management Revision 10
5–33
Parameter Type
(Instruction
Code and
for Command
or Response
Description of Arguments
(Note that all arguments are printable ASCII characters)
Command
(Target to
(Instruction
Code and
Response to Query
(Target to
Controller)
Authentication
Trap
Enable
Sets or returns the SNMP Authentication in the form x, where:
0=Disabled
1=Enabled
SNA?
(See Description of
Arguments)
Enable
Sets or returns SNMP in the form x, where:
0=Disabled
1=Enabled
SNM?
(See Description of
Arguments)
Returns the unit’s nine-digit serial number in the form xxxxxxxxx
Note: this command is functionally identical to RSN.
Example: <1/SNO?’cr’
>0001/SNO=072282040’cr’’lf’
(See Description of
Arguments)
Sets or returns the Physical Address in the form xxxx, where:
xxxx = 0001 to 9999, resolution=0001
Default value: 0001
Example: <1/SPA=0412’cr’
>0001/SPA=’cr’’lf’
SPA?
SPA*
(See Description of
Arguments)
Community
characters, no
spaces
Sets or returns the SNMP Read Community string. Empty string is not allowed
SRC!
(see Description of
Arguments))
System Contact
characters,
Sets or returns the SNMP System Contact string.
Example: <1/SSC=Joe Net Admin.
If not configured it returns empty string: <1/SSC=
SSC!
(see Description of
Arguments)
Interval
Sets or returns the interval at which statistics are logged, in the form xx, where:
xx = 01 to 99 minutes, resolution is in 01 minute increments
Default value: 90
Example: <1/SSI=90’cr’
SSI?
(See Description of
Arguments)