LPOD C-, X-, or Ku-Band Outdoor Amplifier / Block Up Converter (BUC) MN-LPOD
Serial-based Remote Product Management Revision 10
5–24
Parameter Type
(Instruction
Code and
for Command
or Response
Description of Arguments
(Note that all arguments are printable ASCII characters)
Command
(Target to
(Instruction
Code and
Response to Query
(Target to
Controller)
Sets or returns alarm mask conditions in the form abcde, where:
0 = Fault, 1 = Alarm, 2 = Masked
a = Low Forward RF Power
b = External Reference Lock detect
c = Fan Speed
d = LNB Current Detect
e = LNB 22V Power Supply
Default value: 22111
Example: <1/MSK=22111’cr’
MSK?
MSK*
(See Description of
Arguments)
Sets or return the unit mute state in the form x, where:
0 = Disable (Not Muted)
1 = Enable (Muted) (default value)
2 = Unit muted due to AUX mute signal (see Note)
Note: This value is only shown in the response to a query, and cannot be given as a command. When MUT
returns a ‘2’ it indicates that one of the “hardware” mute conditions is present. For example, an auxiliary mute
could be present if the auxiliary mute has been enabled, and the signal to unmute the unit is not provided.
Additionally, certain faults can generate a hardware mute such as the BUC lock detect, the LNB current draw (if
enabled by the user), or the LNB voltage (if enabled by the user). If MUT returns an unexpected value of ‘2’
then check the active faults and the status of the auxiliary mute.
Example: <1/MUT=1’cr’
MUT?
MUT*
(See Description of
Arguments)
Stored Events
Returns the number, in the form xxx, of unread stored events
Example: <1/NUE?’cr’
Stored Statistics
Returns the number, in the form xxx, of unread stored statistics