LPOD C-, X-, or Ku-Band Outdoor Amplifier / Block Up Converter (BUC) MN-LPOD
Serial-based Remote Product Management Revision 10
5–13
Parameter Type
(Instruction
Code and
for Command
or Response
Description of Arguments
(Note that all arguments are printable ASCII characters)
Command
(Target to
(Instruction
Code and
Response to Query
(Target to
Controller)
Status
This is the concise version of the RAS query. Returns the alarm status of the unit, response is semicolon
delimited.
Example: CAS=a;b;c;d;e;f;g;h;i;j;k;I;m;n;o;p;q;r;s;t;u;v;w;x;y;’cr’’lf’ where:
a thru z = 0 (FT), 1 (OK), 2 (AL), 3 (NO), 4 (YS), 5 (MS), 6 (??), or 7 (NA)
a = +24V Power Supply
b = +24V Switch Power Supply
c = +13/18V LNB Power Supply (see Note)
d = +13.5V Power Supply
e = +10V Power Supply
f = +10V1 Amplifier Power Supply
g = +10V2 Amplifier Power Supply (see Note)
h = +7.8V Power Supply
i = +5.8V Power Supply
j = +2.5V Power Supply
k = +1.2V Power Supply
l = -5.8V Power Supply
m = Fan#1 State
n = Fan#2 State (see Note)
o = Heatsink Temp
p = Overtemp Shutdown
q = llC Status
r = Forward Power Alarm
s = Flash Checksum
t = FPGA Done
u = BUC Lock Detect (see Note)
v = External Ref Lock Detect (see Note)
w = LNB Current (see Note)
x = Redundant Switch Condition (see Note)
y = Redundant Link Status (see Note)
z = Terminal Status Change
Notes:
1) c, g, n, u, v, w, x, and y appear if the appropriate model/options have been selected/installed.
2) ?? is an invalid fault condition because hardware failed to respond to query (this value is accompanied by an
I2C fault).
3) NA = not applicable. The unit does not include hardware support for this parameter.
(See Description of
Arguments)