SDM-300L3 Satellite Modem Revision 0
Remote Control Operation MN/SDM300L3.IOM
A–23
A.4.3 ODU Configuration Status
Outdoor Unit
Status
Command:
Response:
<add/OUS_'cr'
>add/OUS_'cr'
CURRENT_xxx'cr'
VOLTAGE_xxx'cr'
TEMP_xxx’cr’
PLL_xxx’cr’
CKSUM_xxx’cr’
SFLT_xx'cr''lf']
Current (FLT/OK)
Voltage (FLT/OK)
Temperature (FLT/OK)
Phase Lock Loop (FLT/OK)
Checksum (FLT/OK)
Number of stored faults logged (0 to 10)
Outdoor Unit
Temperature
Command:
Response:
<add/ODUT_'cr'
>add/ODUT_'cr'
ODU_sxx_yyy'cr’’lf']
Where s = + or – sign, xx = 0 to 99 degree in C and yyy = OK
or OOR (Out of Range).
Outdoor Unit
Phase Lock
Loop
Command:
Response:
<add/OPLL_'cr'
>add/OPLL_xxxxxxxx'cr’’lf']
Where xxxxxxxx = UNLOCKED or OK.
Outdoor Unit
Software
Version
Command:
Response:
<add/OSV_'cr'
>add/OSV_xxcr’’lf']
Where xx = 0 to 15.
Outdoor Unit
Power Class
Command:
Response:
<add/OPC_'cr'
>add/OPC_xxcr’’lf']
Where xx = 2 to 60 Watts
Outdoor Unit
Address
Command:
Response:
<add/OADR_'cr'
>add/OADR_xxcr’’lf']
Where xx = 1 to 15.
Outdoor Unit
TX Output
Command:
Response:
<add/ODUO_'cr'
>add/ODUO_xxcr’’lf']
Where xxx = ON or OFF.
Outdoor Unit
Power
Leveling
Command:
Response:
<add/ODUP_'cr'
>add/ODUP_xxcr’’lf']
Where xxx = ON or OFF.