Comtech EF Data SDM-650B Especificaciones Pagina 159

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 434
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 158
SDM-300L3 Satellite Modem Revision 0
Front Panel Operation MN/SDM300L3.IOM
4–63
FUNCTION SELECT: FAULTS/ALARMS: OUTDOOR UNIT
OUTDOOR UNIT
-----
Note: Faults are only displayed if active.
Fault Active - When:
Current Displays a current fault. ODU (BUC) Power is On and Low or/High Current Alarm set.
Voltage Displays a voltage fault. ODU (BUC) Power is On and ODU Voltage deviates more than
20% from nominal.
Temperature Displays a temperature fault. ODU (BUC) Power is On and FSK is ON.
PLL Lock Displays PLL Lock fault. ODU (BUC) Power is On and FSK is ON.
Checksum Displays checksum fault. ODU (BUC) Power is On and FSK is ON.
Vista de pagina 158
1 2 ... 154 155 156 157 158 159 160 161 162 163 164 ... 433 434

Comentarios a estos manuales

Sin comentarios