6–9
TheseInstructionCodes areexplainedincompletedetailinthetablesthatfollow. Note that the TargettoControllerInstructionCode
Qualifiers,describedearlier,thatappearinthe“ResponsetoCommand”columncarrythefollowingmeanings:
=MessageOK.
?ReceivedOK,butinvalidargumentswerefound.
*MessageOK,butnotpermittedincurrentmode.
#MessageOK,butunitisnotinRemotemode.
!Invalidinstruction.
Parameter
Type
Command
(Instruction
& Qualifier)
Number of
Arguments
Description of Arguments
Response to
Command
Query
(Instruction &
Qualifier)
Response to Query
Default
Passwords
DPW= N/A
Command Only.
Resets the admin username/password to:
Username = “comtech”
Password = “comtech”
DPW=
DPW?
DPW*
DPW#
N/A
N/A
GE1 Address IG1= 18 bytes numerical
Command or Query.
Sets the IP Address and network prefix for the 10/100/1000 BaseT GE1 Ethernet
port, in the form aaa.bbb.ccc.ddd/yy, where:
(Permitted ranges – cannot all be zero)
aaa = 0-223
bbb = 0-255
ccc = 0-255
ddd = 0-255
yy = network prefix (range: 8 to 31)
Other restrictions:
If aaa>191, prefix may not be less than 24.
If aaa>127, prefix may not be less than 16.
Example: IG1=010.006.030.001/24
IG1=
IG1?
IG1*
IG1#
IG1?
IG1=xxx.xxx.xxx.xxx/yy
(see Description of Arguments)