CDM-710 Broadcast Satellite Modem Revision 10
Front Panel Operation MN/CDM710.IOM
ASI2 Rx PLL Upper Limit Reached ASI Rx PLL Upper Limit Reached Slot 2
Rx DCM Unlocked Demod Digital Clock Manager unlocked
ASI1 Rx SERDES Parity Error ASI Rx SERDES parity error Slot 1
ASI1 Rx SERDES Unlock ASI Rx SERDES not locked Slot 1
ASI2 Rx SERDES Parity Error ASI Rx SERDES parity error Slot 2
ASI2 Rx SERDES Unlock ASI Rx SERDES not locked Slot 2
HSSI1 Rx Buffer Underflow HSSI Rx buffer has underrun Slot 1
HSSI1 Rx Buffer Overflow HSSI Rx buffer has overflowed Slot 1
HSSI2 Rx Buffer Underflow HSSI Rx buffer has underrun Slot 2
HSSI2 Rx Buffer Overflow HSSI Rx buffer has overflowed Slot 2
SERDES Par Framer -> Intf1 SERDES parity error detected on framer FPGA interface 1
SERDES Par Framer ->Intf2 SERDES parity error detected on framer FPGA interface 2
Rx Clock Source Interface 1 Rx Clock Source fault Interface 1
Rx Clock Source Interface 2 Rx Clock Source fault Interface 2
If Stored Events: ÆClear-All is selected:
Clear All Stored Events
No Yes (E)
When In Local mode: Using the arrow keys, select No to retain, or Yes to clear the buffer
of all stored events. The User should then press
ENTER.
Note: When the unit is in Remote mode, and the User attempts to use this menu (i.e., by using
the arrow keys), the following message is displayed:
THIS UNIT IS CURRENTLY
IN REMOTE MODE!!
5.3.3 (SELECT:) Test
Test:
Mode TestPatterns (E)
Test selections for the Tx carrier and Patterns are selected in this menu. Select Mode or
TestPatterns using the arrow keys. The User should then press
ENTER.
5–47