Comtech EF Data CDM-710L Especificaciones Pagina 231

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 252
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 230
CDM-710 Broadcast Satellite Modem Revision 10
Remote Control MN/CDM710.IOM
A–69
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for Command
or Response
to Query
Description of Arguments
Response
to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
C=Rx Traffic Status
0=No faults
1=+1.5 Demod Power Supply Unit (Demodulator Card)
2=FPGA Load (Demodulator Card)
3=Demod Unlocked
4=DSNG Sync Error
5=FPGA Temperature (Demodulator Card)
6=Reserved
7=AGC Level Out of Range
8=Eb/No Limit Exceeded
9=Demodulator Synth 1 PLL
A=Demodulator Synth 2 PLL
B= SERDES Demod to Framer
C= SERDES Framer to FEC1
D= SERDES Framer to FEC2
E= Reserved
F= MPEG transport stream error.
G=ASI Rx PLL Empty (Interface 1)
H=ASI Rx PLL Full (Interface 1)
I=ASI Rx PLL Lower Limit Reached (Interface 1)
J=ASI Rx PLL Upper Limit Reached (Interface 1)
K= Reserved
L= Reserved
M= Reserved
N= Reserved
O=Reserved
P=ASI Rx SERDES Error (Interface 1)
Q=ASI Rx SERDES DCM Unlocked (Interface 1)
R= Reserved
S= Reserved
T=HSSI Rx Buffer Underrun (Interface 1)
U=HSSI Rx Buffer Overflow (Interface 1)
V= Reserved
W= Reserved
X=Framer SERDES Rx Fault (Interface 1)
Y=Framer SERDES Rx Fault (Interface 2)
Z=Reserved
[=Reserved
D=New Faults
0=No new faults
1=New faults, since last check
Vista de pagina 230