CDM-710 Broadcast Satellite Modem Revision 11
Appendix A MN/CDM710.IOM
A–8
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
uto Switch
Mode
ASW= 1 byte Command or Query.
Unit returns the redundancy auto/manual mode of the unit in the form x, where:
0 = Manual
1 = Automatic
Example: ASW=0 (Manual Mode selected)
ASW=
ASW?
ASW*
ASW#
ASW? ASW=x
(See Description of
Arguments)
SI Tx Frame
Size
ATF= 2 bytes Command or Query.
Indicates whether the ASI Tx Frame Size is 188 or 204 bytes (ASI card only), in
the form sf, where:
s = interface slot ( 1 or 2 )
f = frame size
0 = 188 bytes
1 = 204 bytes
Example: ATF=11 (Interface Slot 1 set to 204 byte frame size)
ATF=
ATF?
ATF*
ATF#
ATF?s ATF=sf
Clear All Stored
Events
CAE= None Command only.
Forces the software to clear the software events log.
Example: CAE=
Note: This command takes no arguments
CAE=
CAE?
CAE*
CAE#
N/A N/A
Circuit ID String
CID= 24 bytes Command or Query.
Sets or queries the user-defined Circuit ID string, which is a fixed length of 24
characters.
Valid characters include: Space ( ) * + – , . / 0 9 and A thru Z
CID=
CID?
CID*
CID#
CID? CID=xxxxxxxxxxxxxxxxxxxxxx
xx
Configuration
Load
CLD= 1 byte Command Only
Retrieves a previously stored configuration from the specified configuration
location (0 to 9).
Example: CLD=4 (retrieve configuration from Location 4)
CLD=
CLD?
CLD*
CLD#
N/A N/A
Configuration
Save
CST= 1 byte Command only.
Stores the current configuration in the specified configuration location (0 to 9).
Example: CST=4 (store the current configuration in Location 4)
CST=
CST?
CST*
CST#
N/A N/A
Real-time Clock
Date
DAY= 6 bytes Command or Query.
A date in the form ddmmyy, where
dd = day of the month (01 to 31),
mm = month (01 to 12)
yy = year (00 to 99)
Example: DAY=240457 (April 24, 2057)
DAY=
DAY?
DAY*
DAY#
DAY? DAY=ddmmyy