Comtech EF Data SDM-650B Especificaciones Pagina 213

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 348
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 212
SDM-650B Satellite Modem Remote Control Operation
Rev. 6 B–37
B.2.3.4 Set Modulator Output Power Level
Command: <add/MOP_snn.n”cr”
Response: >add/MOP_snn.n”cr””lf”]
Status Only: <add/MOP_”cr”
Response: >add/MOP_snn.n”cr””lf”]
Where:
snn.n = +20.0 to -45.0, in 0.5 dB increments for 140 MHz modulator.
snn.n = +20.0 to -30.0, in 0.5 dB increments for 70 MHz modulator.
Notes:
1. Must be within 25.0 dB of the modulator power offset value (see MPO_) for the
140 MHz modulator, and within 10.0 dB of the modulator power offset for the
70 MHz modulator.
2. When local AUPC enable is programmed ON, the (MOP) Modulator Output
Power command is not allowed; only MOP status is allowed. See “LPC_”
command.
Vista de pagina 212
1 2 ... 208 209 210 211 212 213 214 215 216 217 218 ... 347 348

Comentarios a estos manuales

Sin comentarios