SDM-650B Satellite Modem Remote Control Operation
Rev. 6 B–17
B.1.3.24.1 Buffer Clock
Command: <add/BC_xxx”cr”
Response: >add/BC_xxx”cr””lf”]
Status Only: <add/BC_”cr”
Response: >add/BC_xxx”cr””lf”]
Where: xxx = TXC, RXC, or EXT.
Note: This command is only valid when Buffer Control is enabled. See the “BUFF_”
command definition.
B.1.3.24.2 Interface Buffer Center
This command centers the Doppler buffer.
Command: <add/IBC_”cr”
Response: >add/IBC_”cr””lf”]
Note: This command is only valid when Buffer Control is enabled. See the “BUFF_”
command definition.
B.1.3.24.3 Interface Buffer Size
This command sets the Doppler buffer depth in bits.
Command: <add/IBS_nnnnn”cr”
Response: >add/IBS_nnnnn”cr””lf”]
Status Only: <add/IBS_”cr”
Response: >add/IBS_nnnnn”cr””lf”]
Notes:
1. Valid buffer depths are 512, 1024, 2048, 4096, 8192, 16384, and 32768.
2. This command is only valid when Buffer Control is enabled. See the “BUFF_”
command definition.