LPODnet M&C Netbook Accessory Revision 3
Setup MN-LPODNET
2–7
Connect the CA-0000352 Ethernet Interface Cable’s P1 19-pin circular connector to the
Redundant Loop Cable Assembly ‘J1’ receptacle as shown in Figure 2-9.
2.3 1:1 Redundancy Applications – Cabling Requirements
Figure 2-10 and Figure 2-11 show the SSPA 1:1 Redundancy System cabling requirements.
See Figure 2-9 for an example of the CA-0000352P1-to- Redundant Loop Cable Assembly User
M&C ‘J1 connection.
2.4 Energizing the RF Equipment
If the waveguide is not terminated correctly, it transmits dangerous levels of
electromagnetic
radiation. THIS CAN CAUSE INJURY. Before you energize or operate
any SSPA
waveguide unit, make sure to correctly terminate the waveguide on the
‘J2 | RF OUT’ port.
The LPOD Outdoor Amplifiers / Block Up Converters (BUCs) and the SPOD Outdoor
Amplifiers
do not have Power On/Off switches. Use the ’J3 | POWER IN’ connector
to energize the system.
Step Task
1
Make sure the SSPA is connected correctly to the LPODnet as defined in Sect. 2.2.
2 Connect the applicable prime power source to the SSPA ‘J3 | POWER IN’ port.
3 Energize all components in the system.
2.5 LPODnet Operation
Chapter 3. ETHERNET-BASED M&C USING THE LPODnet
As accessed by the LPODnet , the SSPA’s 100BaseT/10BaseTx Ethernet Management Interface
supports three management protocols:
SNMP with public and private MIB
Telnet Client interface for remote product M&C
Web Server (HTTP) Interface for complete product management