Comtech EF Data Vipersat 564L Guía de usuario Pagina 69

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 176
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 68
Chapter 3 - Using the Command Line Interface (CLI) 3-35
MN/22137, rev 1 Vi per sat Con fig ura t io n
A default setting (95%) is provided, but there may be unique network configura-
tions which require modifying the STDMA Slot Capacity value.
STDMA Switch Delay
In order to minimize unnecessary switching from STDMA to SCPC due to tran-
sient conditions, such as a temporary spike in network traffic for example, a
switch delay parameter is provided. This setting is used to specify a delay before
a switch occurs.
A default value (10 seconds) is provided, but this value can be changed to
accommodate a unique network configuration or application. To change this
setting, enter W at the command prompt in figure 3-43 to display the screen
shown in figure 3-45.
Figure 3-45
STDMA Switch Delay prompt
Percent Allocation
The Percent Allocation menu item, shown in figure 3-43, allows adding a fixed
percentage to the channel bandwidth request to accommodate additional band-
width requirements which may occur after a switch is made from STDMA to
SCPC mode.
To change this setting, enter E at the command prompt to display the screen
shown in figure 3-46.
Figure 3-46
Percent Allocation prompt
Vista de pagina 68
1 2 ... 64 65 66 67 68 69 70 71 72 73 74 ... 175 176

Comentarios a estos manuales

Sin comentarios