Specifications
18 kbps to 25 Mbps, in 1 bps steps
(modulation, FEC & data interface dependant)
Frequency
50 – 180 MHz (standard) and
950 – 2250 MHz (option)
100 Hz resolution, independent TX and RX operation
Modes
(See User Manual
For Details)
Open network, per IESS-308 / 309 / 310 / 314
transparent, closed network per IESS-315
LDPC / TPC Codec (option)
VersaFEC Codec (option) with ACM or Constant Coding &
Modulation (CCM)
EDMAC Framed with/without AUPC
RS Outer Codec
High rate ESC / Enhanced ESC (ESC++)
Drop & insert (D&I) /Enhanced D&I++ (option)
Quad E1 drop & insert (QDI) (option)
DoubleTalk Carrier-in-Carrier (option)
IESS-308/309
Rate 3/4 QPSK/OQPSK
Viterbi with Reed
Solomon
Rate 3/4 16-QAM
Rate 7/8 16-QAM
See CDM-625A user manual for details
Open network and closed network modes
and TPC (2
nd
Gen)
Codec (Optional
Plug-in Module)
Rate 1/2 BPSK/QPSK/OQPSK
Rate 2/3 QPSK/OQPSK/8PSK/8-QAM
Rate 3/4 QPSK/OQPSK/8PSK/8-QAM/16-QAM
TPC Code Rates
Rate 5/16 BPSK
Rate 21/44 BPSK/QPSK/OQPSK
Rate 3/4 QPSK/OQPSK/8PSK/8-QAM/16-QAM
Rate 7/8 QPSK/OQPSK/8PSK/8-QAM/16-QAM
Rate 0.95 QPSK/OQPSK/8PSK/8-QAM
(Option)
QPSK Rate 0.533, 0.631, 0.706, 0.803
8-QAM Rate 0.576 (ECCM), 0.642, 0.711, 0.780
16-QAM Rate 0.644 (ECCM), 0.731, 0.780, 0.829, 0.853
BPSK 0.493 (ULL)
QPSK 0.493, 0.654, 0.734 (ULL)
(Option)
BPSK Rate 0,489
QPSK Rate 0.489, 0.537, 0.586, 0.611, 0.635, 0.660, 0.684,
0.733
8-ARY Rate 0.521, 0.537, 0.562, 0.586, 0.611, 0.635, 0.660,
0.684, 0.708, 0.733
16-ARY Rate 0.586, 0.611, 0.635, 0.660, 0.684, 0.708,
0.733, 0.757, 0.782
32-ARY Rate 0.660, 0.684, 0.708, 0.733, 0.757, 0.782,
0.801, 0.831, 0.855, 0.879
Short Block:
BPSK Rate 0,489
QPSK Rate 0.489, 0.537, 0.586, 0.611, 0.635, 0.660, 0.684,
0.733
8-ARY Rate 0.521, 0.537, 0.562, 0.586, 0.611, 0.635, 0.660,
0.684, 0.708, 0.733
16-ARY Rate 0.586, 0.611, 0.635, 0.660, 0.684, 0.708,
0.733, 0.757, 0.782
32-ARY Rate 0.660, 0.684, 0.708, 0.733, 0.757, 0.782,
IDR Mode, no RS, - per ITU V.35 (Intelsat variant)
IBS mode, no RS - per IESS-309, externally frame
synchronized
Transparent Closed Network mode, no RS or Turbo coding -
per ITU V.35 (Intelsat variant)
EDMAC mode, no RS coding - externally frame
synchronized - proprietary
Turbo Product Code/LDPC/VersaFEC modes - externally
frame synchronized - proprietary
All RS modes - externally frame synchronized per IESS-
10/100Base-T Ethernet with SNMP, HTTP and Telnet
support, EIA-232, EIA-485 (2- or 4-wire)
Hardware fault, RX and TX traffic alarms, open network
backward alarms
(Input OR Output)
Input: 1, 2, 5, or 10 MHz, -6 dBm to
+10 dBm, 50 Ω/75 Ω (nominal)
Output: 10 MHz, 2.7 V peak-to-peak
± 0.4 V, low impedance output
Data Interfaces
EIA-422/-530 DCE , Up to 14 Mbps
25-pin D-sub (female)
LVDS Serial , Up to 25 Mbps
25-pin D-sub (female)
HSSI Serial , Up to 25 Mbps
G.703 T1, 1.544 Mbps
(Balanced 100 Ω)
9-pin D-sub (female)
or
BNC (female)
(Unbalanced 75 Ω or balanced
(Unbalanced 75 Ω or balanced
G.703 E2, 8.448 Mbps (Unbalanced 75 Ω)
Additional 2.048 Mbps E1 Ports for Quad-
E1 (Balanced 120 Ω)
9-pin D-sub (female)
44-pin High-density D-sub (male)
4-port 10/100Base-T Managed Ethernet
Switch
(Optional Packet Processor Available)
4 x RJ-45
Modulator
± 0.06 ppm (± 6 x 10
-8
), 0° to 50°C (32° to
122°F) with internal reference
5%, 10%, 15%, 20%, 25%, 35%
Better than -60 dBc/4 kHz
(typically <-65 dBc/4kHz)
Measured from 1 to 500 MHz
(50-180 MHz band)
Measured F
0
± 500 MHz
< 0.480° rms double sided, 100 Hz to 1 MHz
(Minimum 16 dB better overall than the Intelsat IESS-
308/309 requirements)
dB/Hz Frequency Offset
-63.0 100 Hz
-73.0 1 kHz
-83.0 10 kHz
-93.0 100 kHz
Fundamental AC line spurious is -42 dBc or lower
The sum of all other single sideband spurious, from
0 to 0.75 x symbol rate, is -48 dBc or lower
0 to -25 dBm, 0.1 dB steps
950-2250 MHz:
0 to -40 dBm, 0.1 dB steps
± 0.5 dB over frequency, data rate, modulation type
and temperature range of 15 to 35° C
± 0.8 dB over frequency, data rate, modulation type
and temperature range of 0 to 50° C
950-2250 MHz:
± 0.7 dB over frequency, data rate, modulation type
and temperature range of 15 to 35° C
± 1.0 dB over frequency, data rate, modulation type
and temperature range of 0 to 50° C
Return Loss
50-180 MHz: 50 Ω/75 Ω, 16 dB minimum return loss
(18 dB typical), BNC connector
950-2250 MHz: 50 Ω, 19 dB minimum return loss
(21 dB typical), Type-N connector
Internal, ± 0.06 ppm (SCT)
External, locking over a ± 100 ppm range (TT)
Loop timing (RX satellite clock) – supports
asymmetric operation
By TTL ‘low’ signal or external contact closure
(10 MHz)
Via TX IF center conductor, 10.0 MHz
± 0.06 ppm (with internal reference), selectable
(HW Option)
24 VDC, 4.17 Amps max., 90 W @ 50° C
48 VDC, 3.125 Amps max., 150 W @ 50° C
(180 W @ 30° C)
Supplied through TX IF center conductor and
selectable on/off via M&C control
Comentarios a estos manuales