CSAT-607050 WattC-Band TransceiverInstallation and Operation ManualPart Number MN/CSAT607050.IOM Revision 0
Customer Support Contact the Comtech EF Data Customer Support Department for: • Product support or training • Information on upgrading or returnin
50 Watt C-Band Transceiver Revision 0 Theory of Operation MN/CSAT6070505.IOM D.2 MONITOR & CONTROL The Monitor & Control (M & C) unit i
METRIC CONVERSIONS Units of Length Unit Centimeter Inch Foot Yard Mile Meter Kilometer Millimeter 1 centimeter — 0.3937 0.03281 0
2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 • 333 • 2200 PHONE 480 • 333 • 2161 FAX
Table of Contents CHAPTER 1. INTRODUCTION...
50 Watt C-Band Transceiver Revision 0 Preface MN/CSAT607050.IOM 3.2 Configuring the CSAT ...
50 Watt C-Band Transceiver Revision 0 Preface MN/CSAT607050.IOM C.2 Troubleshooting ...
50 Watt C-Band Transceiver Revision 0 Preface MN/CSAT607050.IOM Figures FIGURE 1-1 CSAT-6070 50 WATT C-BAND TRANSCEIVER ...
50 Watt C-Band Transceiver Revision 0 Preface MN/CSAT607050.IOM Tables TABLE 2-1. UNIVERSAL POLE MOUNT, 50 WATT, AS/0600 ...
50 Watt C-Band Transceiver Revision 0 Preface MN/CSAT607050.IOM About this Manual This manual provides installation and operation information for th
50 Watt C-Band Transceiver Revision 0 Preface MN/CSAT607050.IOM Safety Notice This equipment has been designed to minimize exposure of personnel to
50 Watt C-Band Transceiver Revision 0 Preface MN/CSAT607050.IOM Warranty Policy This Comtech EF Data product is warranted against defects in materi
Chapter 1. INTRODUCTION 1.1 Functional Description ...1–1 This manual provides instructions on the installation, operation and m
50 Watt C-Band Transceiver Revision 0 Introduction MN/CSAT607050.IOM J5COMMJ4EXTERNALREF INJ3ACPOWERJ6IF OUTJ1IF INJ7RF INJ2RF OUTJ1IF INRF O UTJ2
50 Watt C-Band Transceiver Revision 0 Introduction MN/CSAT607050.IOM Figure 1-3 Remote Switch Dimendional drawing 1–3
CSAT-6070 C-Band Transceiver 50 and 100 Watt 50 Watt 100 Watt INTRODUCTION The CSAT-6070 has been developed by a team of RF engineers with many year
CSAT-6070 C-Band Transceiver 50 and 100 Watt Transmit Frequency, RF 6725 to 7025 MHz 6725 to 7025 MHz (Optional Extended) 6725 to 7025 MHz (Op
50 Watt C-Band Transceiver Revision 0 Introduction MN/CSAT506050.IOM 1-6
Chapter 2. INSTALLATION 2.1 Unpacking and Inspection ...1 2.2 Man-Power ...2 2.3 Tools Re
50 Watt Model C-Band Transceiver Revision 0 Installation MN/CSAT607050.IOM 2.2 MAN-POWER Comtech EF Data recommends that two technicians be require
50 Watt Model C-Band Transceiver Revision 0 Installation MN/CSAT607050.IOM 2.4 SINGLE -THREAD CONFIGURATION 2.4.1 MOUNTING KITS The following mount
50 Watt Model C-Band Transceiver Revision 0 Installation MN/CSAT607050.IOM Table 2-2. Universal Pole Mount, AS/0414 Item No. Part No. Nomenclat
50 Watt Model C-Band Transceiver Revision 0 Installation MN/CSAT607050.IOM Table 2-3. CSAT Mounting Brackets, AS/0415 Item No. Part No. Nomenclat
Errata A Comtech EF Data Documentation Update Subject: Add Installation Guidelines Date: July 3, 2003 Document: CSAT-6070 50 Watt C-Band Transcei
50 Watt Model C-Band Transceiver Revision 0 Installation MN/CSAT607050.IOM 2.4.2 SINGLE-THREAD INSTALLATION Refer to Figure 2-3. Figure 2-3. Si
50 Watt Model C-Band Transceiver Revision 0 Installation MN/CSAT607050.IOM 1. Place unistrut brackets (1, Figure 2-1) on a flat surface. 2. Sli
50 Watt Model C-Band Transceiver Revision 0 Installation MN/CSAT607050.IOM 6. Attach bracket (5, figure 2-1) to the strap (4) using two nuts (10)
50 Watt Model C-Band Transceiver Revision 0 Installation MN/CSAT607050.IOM 17. Lift the CSAT unit and slide bolts (6) into the grooves of the bra
50 Watt Model C-Band Transceiver Revision 0 Installation MN/CSAT607050.IOM 2.4.3 LNA INSTALLATION Refer to Figure 2-8. Figure 2-8. Install
50 Watt Model C-Band Transceiver Revision 0 Installation MN/CSAT607050.IOM 2.5 CABLE INSTALLATION Refer to Figure 2-9. Care shall be exercised in
50 Watt Model C-Band Transceiver Revision 0 Installation MN/CSAT607050.IOM 2.6 REDUDANCY CONFIGURATION 2.6.1 MOUNTING KIT AS/0458ASSY, 1:1 C-Band
50 Watt Model C-Band Transceiver Revision 0 Installation MN/CSAT607050.IOM Table 2-4. Final 1:1, C-Band Assembly, AS/0458 Part No. Description
50 Watt Model C-Band Transceiver Revision 0 Installation MN/CSAT607050.IOM Table 2-6. TX Switch Mounting Kit, AS/0437 Item No. Part No. Nomencla
50 Watt Model C-Band Transceiver Revision 0 Installation MN/CSAT607050.IOM Table 2-7. LNA Mounting Kit, AS/0438 Item Part No. Nomenclature QTY
s:\tpubs\manuals\released_word\transceivers\csat6070-50w\text12-11-01\mn-c607050.ea0.doc 2 Change Specifics: Installation guidelines regarding powe
50 Watt Model C-Band Transceiver Revision 0 Installation MN/CSAT607050.IOM Table 2-8 TX/RX Filter Support Bracket AS/0502 Item Part No. Nomencl
50 Watt Model C-Band Transceiver Revision 0 Installation MN/CSAT607050.IOM Table 2-10. Waveguide Kit, CPR137G, AS/0460 Item No. Part No. Nomenc
50 Watt Model C-Band Transceiver Revision 0 Installation MN/CSAT607050.IOM Table 2-11. Waveguide Kit, CPR229, AS/0461 Item Part No. Nomenclature
50 Watt Model C-Band Transceiver Revision 0 Installation MN/CSAT607050.IOM Table 2-12. Waveguide Switch, TX 1:1, AS/0462 Item No. Part No. Nom
50 Watt Model C-Band Transceiver Revision 0 Installation MN/CSAT607050.IOM Table 2-13. Remote Switch Box Assembly, AS/0490 Item Part No. Nomen
50 Watt Model C-Band Transceiver Revision 0 Installation MN/CSAT607050.IOM 2.6.2 REDUNDANCY INSTALLATION Refer to Figure 2-18. Figu
50 Watt Model C-Band Transceiver Revision 0 Installation MN/CSAT607050.IOM 2.6.2.1 ASSEMBLE WAVEGUIDE SWITCH, AS/0462 Refer to Figure 2-19.
50 Watt Model C-Band Transceiver Revision 0 Installation MN/CSAT607050.IOM Figure 2-21. LNA Switch Kit, AS/0438 1. Refer to Table 2-7, Fi
50 Watt Model C-Band Transceiver Revision 0 Installation MN/CSAT607050.IOM 2.6.2.3 ASSEMBLE REDUNDANT CONFIGURATION 1. Place unistrut bracket (1,
50 Watt Model C-Band Transceiver Revision 0 Installation MN/CSAT607050.IOM Figure 2-23. Pipe Blocks Figure 2-24. Looking down a
Errata B Comtech EF Data Documentation Update Subject: Add Table 3-1 for –48V Input Option Date: July 21, 2003 Document: CSAT-6070 50 Watt C-Band
50 Watt Model C-Band Transceiver Revision 0 Installation MN/CSAT607050.IOM 15. Tighten nut to secure the tension strap. 16. Slide two springnut
50 Watt Model C-Band Transceiver Revision 0 Installation MN/CSAT607050.IOM 28. Install the assembled waveguide switch (Figure 2-19) and waveguide
50 Watt Model C-Band Transceiver Revision 0 Installation MN/CSAT607050.IOM 2.7 LNA ASSEMBLY Refer to Table 2-11, Figure2-15 and Figure 2-26. Instal
50 Watt Model C-Band Transceiver Revision 0 Installation MN/CSAT607050.IOM 2.8 CABLE INSTALLATION Refer to Figure 2-27. Care should be exercised i
50 Watt Model C-Band Transceiver Revision 0 Installation MN/CSAT607050.IOM Figure 2-27. Cable Installation 2-30
Chapter 3. SYSTEM OPERATION 3.1 Pin-outs...1 3.2 Turning On the CSAT ...3 3.
/50 Watt C-Band Transceiver Revision 0 System Operation MN/CSAT607050.IOM 3.1.2 CONNECTOR J5: COMM, REMOTE COMMUNICATIONS PORT. Mating connector:
/50 Watt C-Band Transceiver Revision 0 System Operation MN/CSAT607050.IOM 3.2 TURNING ON THE CSAT The CSAT does not contain a ‘Power On/Off’ switc
/50 Watt C-Band Transceiver Revision 0 System Operation MN/CSAT607050.IOM 3.3.3 GAIN OFFSET Both the Receiver and the Transmitter Gain Offsets are
/50 Watt C-Band Transceiver Revision 0 System Operation MN/CSAT607050.IOM The transmitter output state (the ‘RF OUT’ port, J2) will be ON only if
/50 Watt C-Band Transceiver Revision 0 System Operation MN/CSAT607050.IOM Adjust’ which can be varied from 0.0 to 1.0 in 0.1 steps. 0.0 is the defa
/50 Watt C-Band Transceiver Revision 0 System Operation MN/CSAT607050.IOM • If a CSAT was powered ON with ‘Cold Start ON’, the operator can overri
/50 Watt C-Band Transceiver Revision 0 System Operation MN/CSAT607050.IOM Associated Remote Command(s): LCS= Example(s): LCS=1 3.3.14 LNA CURREN
/50 Watt C-Band Transceiver Revision 0 System Operation MN/CSAT607050.IOM 3.3.17 REDUNDANCY CONTROLLER TOGGLE The User can cause the RSU-5060 Redu
/50 Watt C-Band Transceiver Revision 0 System Operation MN/CSAT607050.IOM Example(s): DAY=042900 3.3.21 SET TIME The CSAT contains a battery power
Appendix A. REMOTE CONTROL A.1 Introduction... A-1 A.2 Basic Protocol ... A-2 A.
50 Watt C-Band Transceiver Revision 0 Remote Control MN/CSAT607050.IOM terminal equipment that requires RTS/CTS handshaking. The CSAT simply ties
50 Watt C-Band Transceiver Revision 0 Remote Control MN/CSAT607050.IOM A.2.1 PACKET STRUCTURE Table A-3. Master-to-Slave: Start of Packet Devi
50 Watt C-Band Transceiver Revision 0 Remote Control MN/CSAT607050.IOM A.2.1.2 ADDRESS Up to 9999 devices can be uniquely addressed. In EIA-232 an
50 Watt C-Band Transceiver Revision 0 Remote Control MN/CSAT607050.IOM 2. From Slave to Master, the only permitted values are: = (ASCII code 6
s:\tpubs\manuals\released_word\transceivers\csat6070-50w\errata\mn-c607050-ec0.doc 1 Errata C Comtech EF Data Documentation Update Subject: Changes
50 Watt C-Band Transceiver Revision 0 Remote Control MN/CSAT607050.IOM • If the master sends an instruction code which the slave does not recogni
50 Watt C-Band Transceiver Revision 0 Remote Control MN/CSAT607050.IOM Parameter Type Command (Instruction Code and qualifier) Arguments for Com
50 Watt C-Band Transceiver Revision 0 Remote Control MN/CSAT607050.IOM Parameter Type Command (Instruction Code and qualifier) Arguments for Comm
50 Watt C-Band Transceiver Revision 0 Remote Control MN/CSAT607050.IOM Parameter Type Command (Instruction Code and qualifier) Arguments for Comm
50 Watt C-Band Transceiver Revision 0 Remote Control MN/CSAT607050.IOM Parameter Type Command (Instruction Code and qualifier) Arguments for Comm
50 Watt C-Band Transceiver Revision 0 Remote Control MN/CSAT607050.IOM Parameter Type Command (Instruction Code and qualifier) Arguments for Comm
50 Watt C-Band Transceiver Revision 0 Remote Control MN/CSAT607050.IOM Parameter Type Command (Instruction Code and qualifier) Arguments for Comm
50 Watt C-Band Transceiver Revision 0 Remote Control MN/CSAT607050.IOM Parameter Type Command (Instruction Code and qualifier) Arguments for Comm
50 Watt C-Band Transceiver Revision 0 Remote Control MN/CSAT607050.IOM Parameter Type Command (Instruction Code and qualifier) Arguments for Comm
50 Watt C-Band Transceiver Revision 0 Remote Control MN/CSAT607050.IOM Parameter Type Command (Instruction Code and qualifier) Arguments for Comm
s:\tpubs\manuals\released_word\transceivers\csat6070-50w\errata\mn-c607050-ec0.doc 2 Figure 2-21. LNA Switch Kit, AS/0438-1 1. Refer to Table 2-7
50 Watt C-Band Transceiver Revision 0 Remote Control MN/CSAT607050.IOM Parameter Type Command (Instruction Code and qualifier) Arguments for Comm
50 Watt C-Band Transceiver Revision 0 Remote Control MN/CSAT607050.IOM Parameter Type Command (Instruction Code and qualifier) Arguments for Comm
Appendix B. REDUNDANT SYSTEMS B.1 Redundant System... B-1 B.2 RSU-5060 Operation ... B-7 B.3 Configuri
50 Watt C-Band Transceiver Revision 0 Redundant Systems MN/CSAT607050.IOM B.1.1 RSU-5060 INTERFACES B.1.1.1 ELECTRICAL INTERFACE The RSU-5060 cont
50 Watt C-Band Transceiver Revision 0 Redundant Systems MN/CSAT607050.IOM B.1.1.2 CSAT UNIT A INTERFACE, J1 The J1 interface connector (19-pin) pr
50 Watt C-Band Transceiver Revision 0 Redundant Systems MN/CSAT607050.IOM Table B-4. CSAT B Signal Description (Connector J3) Pin Signal Name
50 Watt C-Band Transceiver Revision 0 Redundant Systems MN/CSAT607050.IOM Table B-6. M&C Signal Description (Connector J5) Pin Signal Name
50 Watt C-Band Transceiver Revision 0 Redundant Systems MN/CSAT607050.IOM B.1.1.8 RX IF INTERFACES, J9 – J11 The Rx IF output signal is fed to the
50 Watt C-Band Transceiver Revision 0 Redundant Systems MN/CSAT607050.IOM B.2 RSU-5060 OPERATION The RSU-5060 is designed to provide single-point
CSAT-6070 50 Watt C-Band Transceiver Installation and Operation Manual Comtech EF Data is an ISO 9001 Registered Company. Part Number MN/CSAT6070
50 Watt C-Band Transceiver Revision 0 Redundant Systems MN/CSAT607050.IOM B.2.1 EIA-485 INTERFACE The RSU-5060 provides a single point interface f
50 Watt C-Band Transceiver Revision 0 Redundant Systems MN/CSAT607050.IOM Rx transfer switches. Like the ‘RED AUTO/MANUAL’ signal above, the ‘SWI
50 Watt C-Band Transceiver Revision 0 Redundant Systems MN/CSAT607050.IOM B.3 CONFIGURING A REDUNDANT SYSTEM Comtech EF Data’s Redundant CSAT syst
Appendix C. MAINTENANCE AND TROUBLESHOOTING C.1 MAINTENANCE TESTING ...2 C.2 TROUBLESHOOTING ...
50 Watt C-Band Transceiver Revision 0 Maintenance and Troubleshooting MN/CSAT607050.IOM C.1 MAINTENANCE TESTING Use the instructions in Chapter 2
50 Watt C-Band Transceiver Revision 0 Maintenance and Troubleshooting MN/CSAT607050.IOM C.3.2 RF CONVERTER MODULE Synthesizer and IFLO Lock Detec
50 Watt C-Band Transceiver Revision 0 Maintenance and Troubleshooting MN/CSAT607050.IOM Transceiver Over Temperature Fault: A fault ("FT&quo
Appendix D. THEORY OF OPERATION D.1 RF Signal Conversion D-2 D.2 Monitor & Control D-4 This appendix contains a general description of the
50 Watt C-Band Transceiver Revision 0 Theory of Operation MN/CSAT6070505.IOM D.1 RF SIGNAL CONVERSION D.1.1 DOWNCONVERTER The RF input to the downc
50 Watt C-Band Transceiver Revision 0 Theory of Operation MN/CSAT6070505.IOM D.1.2 UPCONVERTER The RF input to the upconverter is at 70 ± 18 MHz at